Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography

被引:32
作者
Torikoshi, M
Tsunoo, T
Endo, M
Noda, K
Kumada, M
Yamada, S
Soga, F
Hyodo, K
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
关键词
x-ray computed tomography; synchrotron radiation; monochromatic x ray; electron density;
D O I
10.1117/1.1383062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon flux in a hard x-ray region required for medical applications. The purposes of the synchrotron light source are clinical performance of medical diagnoses clinically and research and development relating with medical applications. One of the most interesting applications for us is dual-energy x-ray computed tomography (CT). It gives the information about electron density of human tissue. The information plays an important role in advancing heavy-ion radiotherapy of cancers. Electron density can be derived from attenuation coefficients measured by different energy x rays. In this paper, a practical method of the dual-energy x-ray CT with synchrotron radiation is proposed with the theoretical consideration. The primitive experiment using monochromatic x rays emitted from radioisotopes proved the procedure of analysis mentioned here effective to derive electron densities from linear attenuation coefficients for two x rays of a different energy. The beamline dedicated to dual-energy x-ray CT is also proposed. It has a multipole wiggler as a light source and it mainly consists of a dual crystal monochromator and a rotating filter for attenuating photon flux of x rays and two-dimensional detector. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 50 条
  • [31] Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation
    Hayakawa, Y.
    Hayakawa, K.
    Inagaki, M.
    Kaneda, T.
    Nakao, K.
    Nogami, K.
    Sakae, T.
    Sakai, T.
    Sato, I.
    Takahashi, Y.
    Tanaka, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 230 - 236
  • [32] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088
  • [33] Minimal detectability of contrast materials in fluorescent x-ray computed tomography using synchrotron radiation
    Yu, Q
    Takeda, T
    Yuasa, T
    Hasegawa, Y
    Zeniya, T
    Hyodo, K
    Itai, Y
    Akatsuka, T
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 230 - 231
  • [34] Dual-energy X-ray backscatter imaging based on attenuation coefficient decomposition
    Wu, Ruohan
    Yang, Yong
    Cao, Zihao
    Wu, Jiping
    Yan, Han
    Liu, Zhengzheng
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [35] Non-destructive analysis of in situ ammonoid jaws by synchrotron radiation X-ray micro-computed tomography
    Takeda, Yusuke
    Tanabe, Kazushige
    Sasaki, Takenori
    Uesugi, Kentaro
    Hoshino, Masato
    PALAEONTOLOGIA ELECTRONICA, 2016, 19 (03)
  • [36] Nondestructive material characterization of meteorites with synchrotron-based high energy x-ray phase micro-computed tomography
    Liu, Huiqiang
    Xiao, Tiqiao
    Xie, Honglan
    Fu, Yanan
    Zhang, Xueliang
    Fan, Xiaoxi
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (05)
  • [37] Diffraction-enhanced X-ray medical imaging at the ELETTRA synchrotron light source
    Menk, RH
    Rigon, L
    Arfelli, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 213 - 220
  • [38] Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source
    Reininger, R.
    Keavney, D. J.
    Borland, M.
    Young, L.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 654 - 659
  • [39] Design of an ultrahigh-energy-resolution and wide-energy-range soft X-ray beamline
    Xue, L.
    Reininger, R.
    Wu, Y. -Q.
    Zou, Y.
    Xu, Z. -M.
    Shi, Y. -B.
    Dong, J.
    Ding, H.
    Sun, J. -L.
    Guo, F. -Z.
    Wang, Y.
    Tai, R. -Z.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 273 - 279
  • [40] Design of an X-ray 3D Microtomography Beamline for Full field Hard X-ray Projection Imaging at the Taiwan Photon Source
    Chang, Shih-Hung
    Chang, Chao-Yu
    Liu, Chin-Yen
    Chang, Chia-Feng
    Chiang, Liang-Chih
    Liao, Bo-Yi
    Chen, Yu-Sheng
    Chen, Hsiang-Hsin
    Yang, Shun-Min
    Lee, Tsung-Tse
    Chen, Ying-Jie
    Chen, Fung-Lan
    Hwu, Yeu-Kuang
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054