Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography

被引:32
作者
Torikoshi, M
Tsunoo, T
Endo, M
Noda, K
Kumada, M
Yamada, S
Soga, F
Hyodo, K
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
关键词
x-ray computed tomography; synchrotron radiation; monochromatic x ray; electron density;
D O I
10.1117/1.1383062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon flux in a hard x-ray region required for medical applications. The purposes of the synchrotron light source are clinical performance of medical diagnoses clinically and research and development relating with medical applications. One of the most interesting applications for us is dual-energy x-ray computed tomography (CT). It gives the information about electron density of human tissue. The information plays an important role in advancing heavy-ion radiotherapy of cancers. Electron density can be derived from attenuation coefficients measured by different energy x rays. In this paper, a practical method of the dual-energy x-ray CT with synchrotron radiation is proposed with the theoretical consideration. The primitive experiment using monochromatic x rays emitted from radioisotopes proved the procedure of analysis mentioned here effective to derive electron densities from linear attenuation coefficients for two x rays of a different energy. The beamline dedicated to dual-energy x-ray CT is also proposed. It has a multipole wiggler as a light source and it mainly consists of a dual crystal monochromator and a rotating filter for attenuating photon flux of x rays and two-dimensional detector. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 50 条
  • [21] A dedicated small-angle X-ray scattering beamline with a superconducting wiggler source at the NSRRC
    Liu, Din-Goa
    Chang, Chien-Hung
    Liu, Chin-Yen
    Chang, Shih-Hung
    Juang, Jwei-Ming
    Song, Yen-Fang
    Yu, Kuan-Li
    Liao, Kuei-Fen
    Hwang, Ching-Shiang
    Fung, Hok-Sum
    Tseng, Ping-Chung
    Huang, Chi-Yi
    Huang, Liang-Jen
    Chung, Shih-Chun
    Tang, Mau-Tsu
    Tsang, King-Long
    Huang, Yu-Shan
    Kuan, Chien-Kuang
    Liu, Yi-Chih
    Liang, Keng S.
    Jeng, U-Ser
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 97 - 104
  • [22] Parameter identification method for dual-energy X-ray imaging
    Osipov, Sergei
    Libin, Eduard
    Chakhlov, Sergei
    Osipov, Oleg
    Shtein, Alexander
    NDT & E INTERNATIONAL, 2015, 76 : 38 - 42
  • [23] Determination of Density Distribution of Tablets Using Synchrotron X-ray Computed Tomography
    Takayama, Kozo
    Otoguro, Saori
    Okada, Nobuto
    Hoshino, Masato
    Yagi, Naoto
    Obata, Yasuko
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (06): : 757 - 762
  • [24] The small-angle X-ray scattering beamline BioMUR at the Kurchatov synchrotron radiation source
    Peters, G. S.
    Zakharchenko, O. A.
    Konarev, P., V
    Karmazikov, Y., V
    Smirnov, M. A.
    Zabelin, A., V
    Mukhamedzhanov, E. H.
    Veligzhanin, A. A.
    Blagov, A. E.
    Kovalchuk, M., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 945
  • [25] Optical design of micro-focus X-ray photon correlation spectroscopy beamline at Shenzhen Light Source
    Lei, Tao
    Tan, Yonggen
    Zhang, Zheng
    Chen, Siyuan
    Feng, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [26] CT Dual-energy Decomposition into X-ray Signatures ρe and Ze
    Martz, Harry E., Jr.
    Seetho, Isaac M.
    Champley, Kyle M.
    Smith, Jerel A.
    Azevedo, Stephen G.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [27] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268
  • [28] Synchrotron radiation used fluorescent X-ray computed tomography as a novel molecular imaging
    Sunaguchi, Naoki
    Huo, Qing Kai
    Nasukawa, Seita
    Maikusa, Norihide
    Fukami, Tadanori
    Yuasa, Tetsuya
    Takeda, Tohoru
    Wu, Jin
    Thet-Thet-Lwin
    Hyodo, Kazuyuki
    Dilmanian, F. Avraham
    Akatsuka, Takao
    PROCEEDINGS OF THE SEVENTH IASTED INTERNATIONAL CONFERENCE ON VISUALIZATION, IMAGING, AND IMAGE PROCESSING, 2007, : 94 - +
  • [29] Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation
    Takeda, T
    Yu, QW
    Yashiro, T
    Yuasa, T
    Hasegawa, Y
    Itai, Y
    Akatsuka, T
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 258 - 267
  • [30] Optimization of the energy for Breast monochromatic absorption X-ray Computed Tomography
    Delogu, Pasquale
    Di Trapani, Vittorio
    Brombal, Luca
    Mettivier, Giovanni
    Taibi, Angelo
    Oliva, Piernicola
    SCIENTIFIC REPORTS, 2019, 9 (1)