Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography

被引:32
作者
Torikoshi, M
Tsunoo, T
Endo, M
Noda, K
Kumada, M
Yamada, S
Soga, F
Hyodo, K
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
关键词
x-ray computed tomography; synchrotron radiation; monochromatic x ray; electron density;
D O I
10.1117/1.1383062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon flux in a hard x-ray region required for medical applications. The purposes of the synchrotron light source are clinical performance of medical diagnoses clinically and research and development relating with medical applications. One of the most interesting applications for us is dual-energy x-ray computed tomography (CT). It gives the information about electron density of human tissue. The information plays an important role in advancing heavy-ion radiotherapy of cancers. Electron density can be derived from attenuation coefficients measured by different energy x rays. In this paper, a practical method of the dual-energy x-ray CT with synchrotron radiation is proposed with the theoretical consideration. The primitive experiment using monochromatic x rays emitted from radioisotopes proved the procedure of analysis mentioned here effective to derive electron densities from linear attenuation coefficients for two x rays of a different energy. The beamline dedicated to dual-energy x-ray CT is also proposed. It has a multipole wiggler as a light source and it mainly consists of a dual crystal monochromator and a rotating filter for attenuating photon flux of x rays and two-dimensional detector. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 50 条
  • [1] Features of dual-energy X-ray computed tomography
    Torikoshi, M
    Tsunoo, T
    Ohno, Y
    Endo, M
    Natsuhori, M
    Kakizaki, T
    Ito, N
    Uesugi, K
    Yagi, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 99 - 105
  • [2] Experimental feasibility of dual-energy computed tomography based on the Thomson scattering X-ray source
    Chi, Zhijun
    Du, Yingchao
    Yan, Lixin
    Wang, Dong
    Zhang, Hongze
    Huang, Wenhui
    Tang, Chuanxiang
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1797 - 1802
  • [3] Design of the Soft X-ray Tomography Beamline at Taiwan Photon Source
    Su, Yi-Jr
    Fu, Huang-Wen
    Chung, Shih-Chun
    Fung, Hok-Sum
    Liu, Din-Goa
    Huang, Liang-Jen
    Yan, Hong-Yi
    Chou, Yu-Ching
    Yin, Gung-Chian
    Lai, Lee-Jene
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [4] A new soft x-ray photoemission microscopy beamline at the National Synchrotron Light Source
    Flege, J. I.
    Vescovo, E.
    Nintzel, G.
    Lewis, L. H.
    Hulbert, S.
    Sutter, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) : 855 - 858
  • [5] Dual-energy X-ray CT with CdTe array and its extension
    Ohno, Y
    Torikoshi, M
    Tsunoo, T
    Hyodo, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 72 - 77
  • [6] Concept of effective atomic number and effective mass density in dual-energy X-ray computed tomography
    Bonnin, Anne
    Duvauchelle, Philippe
    Kaftandjian, Valerie
    Ponard, Pascal
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 318 : 223 - 231
  • [7] K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Busse, Madleen
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [8] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [9] Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction
    Sasaya, Tenta
    Sunaguchi, Naoki
    Thet-Thet-Lwin
    Hyodo, Kazuyuki
    Zeniya, Tsutomu
    Takeda, Tohoru
    Yuasa, Tetsuya
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Data Acquisition and Analysis at the X-ray Computed Tomography Beamline of SESAME
    Iori, Gianluca
    Matalgah, Salman
    Chrysostomou, Charalambos
    Al-Dalleh, Abdalla
    Alzu'bi, Mustafa
    2021 IEEE JORDAN INTERNATIONAL JOINT CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION TECHNOLOGY (JEEIT), 2021, : 134 - 139