Double-crowned valved stents for off-pump mitral valve replacement

被引:54
作者
Ma, L
Tozzi, P
Huber, CH
Taub, S
Gerelle, G
von Segesser, LK
机构
[1] CHU Vaudois, Serv Chirurg Cardiovasc BH10, Dept Cardiovasc Surg, CH-1011 Lausanne, Switzerland
[2] Zhejiang Univ, Coll Med, Affiliated Hosp 1, Cardiothorac Dept, Hangzhou 310027, Peoples R China
关键词
self-expandabte valved stent; mitral valve replacement; off-pump cardiac surgery;
D O I
10.1016/j.ejcts.2004.12.068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An animal model has been designed to assess the feasibility of off-pump mitral valve replacement using valved stents. Methods: Glutaraldehyde-preserved homograft was sutured inside a prosthetic tube (Dacron). Then, two self-expandable nitinol Z-stents were sutured on the external surface of the prosthesis in such a way to create two self-expanding crowns for fixation. In adult pigs and under general anesthesia, the left atrium was exposed through a left thoracotomy and atrio-ventricutar roadmapping was performed with intravascular ultrasound (IVUS) and fluoroscopy. The double-crowned valved stents were loaded into a delivery sheath. The sheath was then introduced into the left atrium and the valved stents was deployed in mitral position in such a way that the part in between the two stents was at the level of the mitral. annulus. Intracardiac Unltrasound (ICUS) was used to assess the valve function. Hemodynamic parameters were gathered as well. Animal survived for no more than 3 h after the valve deployment and gross anatomy examination of the left heart was carried out. Results: The mean height of the valved stents was 29.4 +/- 0.2 mm, with an internal diameter of 20.4 +/- 1.0 mm, and an external diameter of 25.5 +/- 0.8 mm. The procedure was successfully carried out in eight animals. In vivo evaluation showed a native mitral annulus diameter of 24.9 +/- 0.6 mm, and a mean mitral valve area of 421.4 +/- 17.5 mm(2). ICUS showed a mild mitral. regurgitation in three out of eight animals. Mean pressure gradient across the valved stents was 2.6 +/- 3.1 mmHg. Mean pressure gradient across the left ventricular outflow tract (LVOT) was 6.6 +/- 5.2 mmHg. The mean survival time was 97.5 +/- 56.3 min (survival time range was 40-180 min). One animal died due to the occlusion of the LVOT because of valved stents displacement. Postmortem evaluation confirmed correct positioning of the valved stent in the mitral position in seven out of eight animals. No atrial. or ventricutar lesions due to the valved stents were found. Conclusions: Off-pump implantation of a self-expandable valved stent in the mitral position is technically feasible. Further studies will assess if this procedure is also feasible in humans. (c)) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:194 / 198
页数:5
相关论文
共 16 条
  • [1] ANDERTON R, 1992, GEOLOGICAL SOC LONDO, V13, P5
  • [2] Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Merckx, J
    Aggoun, Y
    Bonnet, D
    Acar, P
    Le Bidois, J
    Sidi, D
    Kachaner, J
    [J]. LANCET, 2000, 356 (9239) : 1403 - 1405
  • [3] Transcatheter implantation of a bovine valve in pulmonary position - A lamb study
    Bonhoeffer, P
    Boudjemline, Y
    Saliba, Z
    Hausse, AO
    Aggoun, Y
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. CIRCULATION, 2000, 102 (07) : 813 - 816
  • [4] Percutaneous insertion of the pulmonary valve
    Bonhoeffer, P
    Boudjemline, Y
    Qureshi, SA
    Le Bidois, J
    Iserin, L
    Acar, P
    Merckx, J
    Kachaner, J
    Sidi, D
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (10) : 1664 - 1669
  • [5] Steps toward percutaneous aortic valve replacement
    Boudjemline, Y
    Bonhoeffer, P
    [J]. CIRCULATION, 2002, 105 (06) : 775 - 778
  • [6] Corno Antonio F, 2003, Interact Cardiovasc Thorac Surg, V2, P166
  • [7] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB
    [J]. CIRCULATION, 2002, 106 (24) : 3006 - 3008
  • [8] DAVIES H, 1965, LANCET, V1, P250
  • [9] HALEES ZA, 1999, J THORAC CARDIOVASC, V117, P614
  • [10] Do valved stents compromise coronary flow?
    Huber, CH
    Tozzi, P
    Corno, AF
    Marty, B
    Ruchat, P
    Gersbach, P
    Nasratulla, M
    von Segesser, LK
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (05) : 754 - 759