Meaningful change: Defining the interpretability of changes in endpoints derived from interactive and mHealth technologies in healthcare and clinical research

被引:18
作者
Byrom, B. [1 ]
Breedon, P. [2 ]
Tulkki-Wilke, R. [3 ]
Platko, J., V [4 ]
机构
[1] Signant Hlth, Prod Management, London, England
[2] Nottingham Trent Univ, Med Design Res Grp, Nottingham, England
[3] Signant Hlth, Prod Management, Helsinki, Finland
[4] Signant Hlth, Prod Management, Plymouth Meeting, PA USA
关键词
Meaningful change; outcome measurement; interpretability; clinical endpoints; statistical analysis (medical); VIRTUAL-REALITY; MICROSOFT KINECT; REHABILITATION; CHILDREN;
D O I
10.1177/2055668319892778
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Immersive, interactive and mHealth technologies are increasingly being used in clinical research, healthcare and rehabilitation solutions. Leveraging technology solutions to derive new and novel clinical outcome measures is important to the ongoing assessment of clinical interventions. While demonstrating statistically significant changes is an important element of intervention assessment, understanding whether changes detected reflect changes of a magnitude that are considered meaningful to patients is equally important. We describe methodologies used to determine meaningful change and recommend that these techniques are routinely included in the development and testing of clinical assessment and rehabilitation technology solutions.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 32 条
[1]  
[Anonymous], 2018, Patient-Focused Drug Development: Collecting Comprehensive and Representative Input
[2]   Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework [J].
Atkinson, AJ ;
Colburn, WA ;
DeGruttola, VG ;
DeMets, DL ;
Downing, GJ ;
Hoth, DF ;
Oates, JA ;
Peck, CC ;
Schooley, RT ;
Spilker, BA ;
Woodcock, J ;
Zeger, SL .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 2001, 69 (03) :89-95
[3]  
Barry G, 2014, J NEUROENG REHABIL, V11, DOI [10.1186/1743-0003-11-33, 10.1186/1743-0003-11-60]
[4]  
Bashiri A, 2018, IRAN J PUBLIC HEALTH, V47, P140
[5]   Using perceptive computing in multiple sclerosis the Short Maximum Speed Walk test [J].
Behrens, Janina ;
Pfueller, Caspar ;
Mansow-Model, Sebastian ;
Otte, Karen ;
Paul, Friedemann ;
Brandt, Alexander U. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
[6]   How a well-grounded minimal important difference can enhance transparency of labelling claims and improve interpretation of a patient reported outcome measure [J].
Brozek, Jan L. ;
Guyatt, Gordon H. ;
Schuenemann, Holger J. .
HEALTH AND QUALITY OF LIFE OUTCOMES, 2006, 4 (1)
[7]   Virtual Reality in Health System: Beyond Entertainment. A Mini-Review on the Efficacy of VR During Cancer Treatment [J].
Chirico, Andrea ;
Lucidi, Fabio ;
De Laurentiis, Michele ;
Milanese, Carla ;
Napoli, Alessandro ;
Giordano, Antonio .
JOURNAL OF CELLULAR PHYSIOLOGY, 2016, 231 (02) :275-287
[8]   Instrumenting gait assessment using the Kinect in people living with stroke: reliability and association with balance tests [J].
Clark, Ross A. ;
Vernon, Stephanie ;
Mentiplay, Benjamin F. ;
Miller, Kimberly J. ;
McGinley, Jennifer L. ;
Pua, Yong Hao ;
Paterson, Kade ;
Bower, Kelly J. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12 :15
[9]   The Minimal Important Difference in Physical Activity in Patients with COPD [J].
Demeyer, Heleen ;
Burtin, Chris ;
Hornikx, Miek ;
Camillo, Carlos Augusto ;
Van Remoortel, Hans ;
Langer, Daniel ;
Janssens, Wim ;
Troosters, Thierry .
PLOS ONE, 2016, 11 (04)
[10]   ASSESSING THE RESPONSIVENESS OF FUNCTIONAL SCALES TO CLINICAL-CHANGE - AN ANALOGY TO DIAGNOSTIC-TEST PERFORMANCE [J].
DEYO, RA ;
CENTOR, RM .
JOURNAL OF CHRONIC DISEASES, 1986, 39 (11) :897-906