Optimizing MRI sequences and images for MRI-based stereotactic radiosurgery treatment planning

被引:13
|
作者
Taghizadeh, Somayeh [1 ,2 ,4 ,5 ]
Labuda, Cecille [4 ,5 ]
Yang, Claus Chunli [1 ]
Morris, Bart [1 ]
Kanakamedala, Madhava R. [1 ]
Vijayakumar, Srinivasan [1 ]
Rey-Dios, Roberto [1 ,3 ]
Duggar, William N. [1 ]
Florez, Edward [2 ]
Fatemi, Ali [1 ,2 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Radiat Oncol, 2500 North State St, Jackson, MS 39216 USA
[2] Univ Mississippi, Med Ctr, Dept Radiol, Jackson, MS 39216 USA
[3] Univ Mississippi, Med Ctr, Dept Neurosurg, Jackson, MS 39216 USA
[4] Univ Mississippi, Natl Ctr Phys Acoust, Jackson, MS 38655 USA
[5] Univ Mississippi, Dept Phys & Astron, Jackson, MS 38655 USA
关键词
MRI; Stereotactic radiosurgery planning; Tumor; COMPLETE DISTORTION CORRECTION; POINT-SPREAD FUNCTION; GEOMETRIC DISTORTION;
D O I
10.1016/j.rpor.2018.09.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: Development of MRI sequences and processing methods for the production of images appropriate for direct use in stereotactic radiosurgery (SRS) treatment planning. Background: MRI is useful in SRS treatment planning, especially for patients with brain lesions or anatomical targets that are poorly distinguished by CT, but its use requires further refinement. This methodology seeks to optimize MRI sequences to generate distortion-free and clinically relevant MR images for MRI-only SRS treatment planning. Materials and methods: We used commercially available SRS MRI-guided radiotherapy phantoms and eight patients to optimize sequences for patient imaging. Workflow involved the choice of correct MRI sequence(s), optimization of the sequence parameters, evaluation of image quality (artifact free and clinically relevant), measurement of geometrical distortion, and evaluation of the accuracy of our offline correction algorithm. Results: CT images showed a maximum deviation of 1.3 mm and minimum deviation of 0.4 mm from true fiducial position for SRS coordinate definition. Interestingly, uncorrected MR images showed maximum deviation of 1.2 mm and minimum of 0.4 mm, comparable to CT images used for SRS coordinate definition. After geometrical correction, we observed a maximum deviation of 1.1 mm and minimum deviation of only 0.3 mm. Conclusion: Our optimized MRI pulse sequences and image correction technique show promising results; MR images produced under these conditions are appropriate for direct use in SRS treatment planning. Published by Elsevier Sp. z o.o. on behalf of Greater Poland Cancer Centre.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 50 条
  • [1] MRI-based treatment planning for brain stereotactic radiosurgery: Dosimetric validation of a learning-based pseudo-CT generation method
    Wang, Tonghe
    Manohar, Nivedh
    Lei, Yang
    Dhabaan, Anees
    Shu, Hui-Kuo
    Liu, Tian
    Curran, Walter J.
    Yang, Xiaofeng
    MEDICAL DOSIMETRY, 2019, 44 (03) : 199 - 204
  • [2] Image distortion in MRI-based polymer gel dosimetry of Gamma Knife stereotactic radiosurgery systems
    Watanabe, Y
    Perera, GM
    Mooij, RB
    MEDICAL PHYSICS, 2002, 29 (05) : 797 - 802
  • [3] Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
    Schmidt, M. A.
    Wells, E. J.
    Davison, K.
    Riddell, A. M.
    Welsh, L.
    Saran, F.
    MEDICAL PHYSICS, 2017, 44 (02) : 375 - 381
  • [4] Optimizing packing contrast for MRI-based intracavitary brachytherapy planning for cervical cancer
    Swanick, Cameron W.
    Castle, Katherine O.
    Rechner, Laura A.
    Rauch, Gaiane M.
    Jhingran, Anuja
    Eifel, Patricia J.
    Klopp, Ann H.
    BRACHYTHERAPY, 2015, 14 (03) : 385 - 389
  • [5] MRI-Based Proton Treatment Planning for Base of Skull Tumors
    Shafai-Erfani, Ghazal
    Lei, Yang
    Liu, Yingzi
    Wang, Yinan
    Wang, Tonghe
    Zhong, Jim
    Liu, Tian
    McDonald, Mark
    Curran, Walter J.
    Zhou, Jun
    Shu, Hui-Kuo
    Yang, Xiaofeng
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2019, 6 (02): : 12 - 25
  • [6] Geometric inaccuracy and co-registration errors for CT, DynaCT and MRI images used in robotic stereotactic radiosurgery treatment planning
    Aldosary, Ghada
    Szanto, Janos
    Holmes, Oliver
    Lavigne, Bernie
    Althobaity, Waleed
    Sheikh, Adnan
    Foottit, Claire
    Vandervoort, Eric
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 212 - 222
  • [7] MRI-based IMPT planning for prostate cancer
    Depauw, Nicolas
    Keyrilainen, Jani
    Suilamo, Sami
    Warner, Lizette
    Bzdusek, Karl
    Olsen, Christine
    Kooy, Hanne
    RADIOTHERAPY AND ONCOLOGY, 2020, 144 : 79 - 85
  • [8] MRI distortion: considerations for MRI based radiotherapy treatment planning
    Amy Walker
    Gary Liney
    Peter Metcalfe
    Lois Holloway
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 103 - 113
  • [9] MRI distortion: considerations for MRI based radiotherapy treatment planning
    Walker, Amy
    Liney, Gary
    Metcalfe, Peter
    Holloway, Lois
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (01) : 103 - 113
  • [10] MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method
    Liu, Yingzi
    Lei, Yang
    Wang, Tonghe
    Kayode, Oluwatosin
    Tian, Sibo
    Liu, Tian
    Patel, Pretesh
    Curran, Walter J.
    Ren, Lei
    Yang, Xiaofeng
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1100):