A novel flow injection chemiluminescence determination of Cr(VI) with Dichlorotris(1,10-phenanthroline)ruthenium(II)

被引:17
作者
Luaces, M. D. [2 ]
Martinez, N. C. [2 ]
Granda, M. [2 ]
Valdes, A. C. [3 ]
Perez-Conde, C. [1 ]
Gutierrez, A. M. [1 ]
机构
[1] Univ Complutense, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
[2] Univ Havana, Fac Chem, Havana 10400, Cuba
[3] Univ Havana, Inst Mat Sci, Havana 10400, Cuba
关键词
Chemiluminescence; Cr(VI); Dichlorotris(1,10-phenanthroline)ruthenium(II); Flow injection; SOLID-PHASE EXTRACTION; CHROMIUM; CHROMATOGRAPHY; LUMINESCENCE; SPECIATION;
D O I
10.1016/j.talanta.2011.07.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective novel reverse flow injection system with chemiluminescence detection (rFI-CL) for the determination of Cr(VI) in presence of Cr(III) with Dichlorotris (1,10-phenanthroline)ruthenium(II), (Ru(phen)(3)Cl-2), is described in this work. This new method is based on the oxidation capacity of Cr(VI) in H2SO4 media. First, the Ruthenium(II) complex is oxidized to Ruthenium(III) complex by Cr(VI) and afterwards it is reduced to the excited state of the Ruthenium(II) complex by a sodium oxalate solution, emitting light inside the detector. The intensity of chemiluminescence (CL) is proportional to the concentration of Cr(VI) and, under optimum conditions, it can be determined over the range of 3-300 mu g L-1 with a detection limit of 0.9 mu g L-1. The RSD was 8.4% and 1.5% at 5 and 50 mu g L-1, respectively. For the rFI-CL method various analytical parameters were optimized: flow rate (1 mL min(-1) H2SO4 carrier concentration (20% w/V), Ru(phen)(3)Cl-2 concentration (5 mM) and sodium oxalate concentration (0.1 M). The effect of Cr(III), Fe(III), Al(III), Cd(II), Zn(II), Hg(II), Pb(II), Ca(II) and Mg(II), was studied. The method is highly sensitive and selective, allowing a fast, on-line determination of Cr(VI) in the presence of Cr(III). Finally, the method was tested in four different water samples (tap, reservoir, well and mineral), with good recovery percentage. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1904 / 1908
页数:5
相关论文
共 24 条
  • [1] [Anonymous], 1967, OFFICIAL J EURO 0627
  • [2] Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD)
    Cathum, S
    Brown, CE
    Wong, W
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) : 103 - 110
  • [3] Speciation of chromium in mineral waters and salinas by solid-phase extraction and graphite furnace atomic absorption spectrometry
    Chwastowska, J
    Skwara, W
    Sterlinska, E
    Pszonicki, L
    [J]. TALANTA, 2005, 66 (05) : 1345 - 1349
  • [4] Comparison of homoleptic and heteroleptic 2,2′-bipyridine and 1,10-phenanthroline ruthenium complexes as chemiluminescence and electrochemiluminescence reagents in aqueous solution
    Cooke, Michaela M.
    Doeven, Egan H.
    Hogan, Conor F.
    Adcock, Jacqui L.
    McDermott, Geoffrey P.
    Conlan, Xavier A.
    Barnett, Neil W.
    Pfeffer, Frederick M.
    Francis, Paul S.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 635 (01) : 94 - 101
  • [5] Spectrofluorometric determination and chemical speciation of trace concentrations of chromium (III & VI) species in water using the ion pairing reagent tetraphenyl-phosphonium bromide
    El-Shahawi, M. S.
    Al-Saidi, H. M.
    Bashammakh, A. S.
    Al-Sibaai, A. A.
    Abdelfadeel, M. A.
    [J]. TALANTA, 2011, 84 (01) : 175 - 179
  • [6] Analytical applications of flow injection with chemiluminescence detection - a review
    Fletcher, P
    Andrew, KN
    Calokerinos, AC
    Forbes, S
    Worsfold, PJ
    [J]. LUMINESCENCE, 2001, 16 (01) : 1 - 23
  • [7] Tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence
    Gorman, BA
    Francis, PS
    Barnett, NW
    [J]. ANALYST, 2006, 131 (05) : 616 - 639
  • [8] Separation of chromium(III) and chromium(VI) by ion chromatography and an inductively coupled plasma mass spectrometer as element-selective detector
    Hagendorfer, Harald
    Goessler, Walter
    [J]. TALANTA, 2008, 76 (03) : 656 - 661
  • [9] Flow injection fluorimetric determination of chromium(VI) in electroplating baths by luminescence quenching of tris(2,2′-bipyridyl) ruthenium(II)
    Hassan, SSM
    Abdel-Shafi, AA
    Mohammed, AHK
    [J]. TALANTA, 2005, 67 (04) : 696 - 702
  • [10] Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reaction
    Du, Jian-Xiu
    Li, Yin-Huan
    Guan, Rong
    [J]. MICROCHIMICA ACTA, 2007, 158 (1-2) : 145 - 150