Hybrid seismic control of buildings using tuned mass and magnetorheological dampers

被引:12
作者
Bhaiya, Vishisht [1 ]
Bharti, Shiv Dayal [2 ]
Shrimali, Mahendra Kumar [2 ]
Datta, Tushar Kanti [3 ,4 ]
机构
[1] Malaviya Natl Inst Technol MNIT, Dept Civil Engn, Jaipur, Rajasthan, India
[2] MNIT, Dept Civil Engn, Jaipur, Rajasthan, India
[3] IIT, Delhi, India
[4] MNIT, NCDMM, Jaipur, Rajasthan, India
关键词
dynamics; seismic engineering; CONTROL STRATEGIES; SYSTEM; PERFORMANCE; BRIDGE;
D O I
10.1680/jstbu.18.00090
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of magnetorheological (MR) dampers in combination with other control devices in a hybrid mode to enhance the control of the seismic responses of building structures is a subject of topical interest. This paper reports on the development of hybrid control schemes using different combinations of MR and tuned mass dampers (TMDs) to control the earthquake responses of building frames. The performance of the hybrid control schemes was evaluated by comparing the results with those of purely semi-active control schemes using three and four MR dampers consecutively placed in the bottom storeys of the frame. For the comparison, responses were obtained using four control strategies, namely a linear quadratic regulator with a clipped algorithm, passive-on, passive-off and a newly developed control strategy called velocity tracking control, which is especially suitable for partially observed states. The study showed that a maximum increase of 40-45% control of response could be achieved using a combination of a TMD and fewer MR dampers.
引用
收藏
页码:471 / 487
页数:17
相关论文
共 50 条
[31]   Optimum design of a sliding mode control for seismic mitigation of structures equipped with active tuned mass dampers [J].
Eliasi, Hussein ;
Yazdani, Hessam ;
Khatibinia, Mohsen ;
Mahmoudi, Mehdi .
STRUCTURAL ENGINEERING AND MECHANICS, 2022, 81 (05) :633-645
[32]   Distributed Tuned Mass Dampers for Multi-Mode Control of Benchmark Building under Seismic Excitations [J].
Elias, Said ;
Matsagar, Vasant ;
Datta, T. K. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2019, 23 (07) :1137-1172
[34]   Semi-active structural vibration control of base-isolated buildings using magnetorheological dampers [J].
Oliveira, Fernando ;
Botto, Miguel Ayala ;
Morais, Paulo ;
Suleman, Afzal .
JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2018, 37 (03) :565-576
[35]   Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings [J].
De Domenico, Dario ;
Deastra, Predaricka ;
Ricciardi, Giuseppe ;
Sims, Neil D. ;
Wagg, David J. .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (14) :7626-7649
[36]   Particle swarm optimization of tuned mass dampers [J].
Leung, A. Y. T. ;
Zhang, Haijun .
ENGINEERING STRUCTURES, 2009, 31 (03) :715-728
[37]   Seismic effectiveness of tuned mass dampers in a life-cycle cost perspective [J].
Matta, Emiliano .
EARTHQUAKES AND STRUCTURES, 2015, 9 (01) :73-91
[38]   Seismic Vibration Mitigation of Wind Turbine Tower Using Bi-Directional Tuned Mass Dampers [J].
Li, Wanrun ;
Zhang, Qing ;
Yang, Zhou ;
Zhu, Qingxin ;
Du, Yongfeng .
MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
[39]   OPTIMAL CONTROL OF GUN RECOIL USING MAGNETORHEOLOGICAL DAMPERS [J].
Singh, Harinder J. ;
Wereley, Norman M. .
PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, VOL 2, 2012, :441-450
[40]   Hybrid active tuned mass dampers for structures under the ground acceleration [J].
Li, Chunxiang ;
Cao, Baoya .
STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (04) :757-773