The influence of a dietary protocol on cone beam CT-guided radiotherapy for prostate cancer patients

被引:73
作者
Smitsmans, Monique H. P. [1 ]
Pos, Floris J. [1 ]
de Bois, Josien [1 ]
Heemsbergen, Wilma D. [1 ]
Sonke, Jan-Jakob [1 ]
Lebesque, Joos V. [1 ]
van Herk, Marcel [1 ]
机构
[1] NKI AVL, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 71卷 / 04期
关键词
diet; image quality of cone beam CT; prostate localization; prostate motion; image-guided radiotherapy;
D O I
10.1016/j.ijrobp.2008.03.036
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the influence of a dietary protocol on cone beam computed tomography (CBCT) image quality, which is an indirect indicator for short-term (intrafraction) prostate motion, and on interfraction motion. Image quality is affected by motion (e.g., moving gas) during imaging and influences the performance of automatic prostate localization on CBCT scans. Methods and Materials: Twenty-six patients (336 CBCT scans) followed the dietary protocol and 23 patients (240 CBCT scans) did not. Prostates were automatically localized by using three dimensional (3D) gray-value registration (GR). Feces and (moving) gas occurrence in the CBCT scans, the success rate of 3D-GR, and the statistics of prostate motion data were assessed. Results: Feces, gas, and moving gas significantly decreased from 55%, 61 %, and 43% of scans in the nondiet group to 31 %, 47 %, and 28% in the diet group (all p < 0.001). Since there is a known relation between gas and short-term prostate motion, intrafraction prostate motion probably also decreased. The success rate of 3D-GR improved from 83% to 94% (p < 0.001). A decrease in random interfraction prostate motion also was found, which was not significant after Bonferroni's correction. Significant deviations from planning CT position for rotations around the left-right axis were found in both groups. Conclusions: The dietary protocol significantly decreased the incidence of feces and (moving) gas. As a result, CBCT image quality and the success rate of 3D-GR significantly increased. A trend exists that random interfraction prostate motion decreases. Using a dietary protocol therefore is advisable, also without CBCT-based image guidance. (C) 2008 Elsevier Inc.
引用
收藏
页码:1279 / 1286
页数:8
相关论文
共 22 条
[1]  
Armitage P., 2001, STAT METHODS MED RES, V4th
[2]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[3]  
De Meerleer G, 2004, RADIOTHER ONCOL, V73, pS405
[4]   Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI) [J].
Ghilezan, MJ ;
Jaffray, DA ;
Siewerdsen, JH ;
van Herk, M ;
Shetty, A ;
Sharpe, MB ;
Jafri, SZ ;
Vicini, FA ;
Matter, RC ;
Brabbins, DS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :406-417
[5]   Quantification of local rectal wall displacements by virtual rectum unfolding [J].
Hoogeman, MS ;
van Herk, M ;
de Bois, J ;
Muller-Timmermans, P ;
Koper, PCM ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2004, 70 (01) :21-30
[6]   Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer [J].
Hoogeman, MS ;
van Herk, M ;
de Bois, J ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (02) :177-185
[7]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[8]   Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy [J].
Kupelian, Patrick ;
Willoughby, Twyla ;
Mahadevan, Arul ;
Djemil, Toufik ;
Weinstein, Geoffrey ;
Jani, Shirish ;
Enke, Charles ;
Solberg, Timothy ;
Flores, Nicholas ;
Liu, David ;
Beyer, David ;
Levine, Lisa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1088-1098
[9]   Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278
[10]   Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer [J].
Lebesque, JV ;
Bruce, AM ;
Kroes, APG ;
Touw, A ;
Shouman, T ;
VanHerk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1109-1119