Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach

被引:17
作者
Anderson, Joseph C. [1 ,2 ]
Kahi, Charles J. [3 ,4 ]
Sullivan, Andrew [3 ]
MacPhail, Margaret [3 ]
Garcia, Jonathan [3 ]
Rex, Douglas K. [3 ]
机构
[1] Dept Vet Affairs Med Ctr, White River Jct, VT USA
[2] Geisel Sch Med Dartmouth, Hanover, NH USA
[3] Indiana Univ Sch Med, Dept Med, Div Gastroenterol & Hepatol, Indianapolis, IN 46202 USA
[4] Richard L Roudebush VA Med Ctr, Indianapolis, IN USA
关键词
WATER-AIDED COLONOSCOPY; UNSEDATED COLONOSCOPY; IMMERSION; EXCHANGE; INFUSION; MULTICENTER;
D O I
10.1016/j.gie.2018.09.046
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Although water exchange may improve adenoma detection compared with CO2, it is unclear whether water is a better medium to fill the lumen during withdrawal and visualize the mucosa. Total underwater colonoscopy (TUC) involves the use of water exchange with the air valve off during insertion followed by the inspection of the mucosa under water. Our goal was to compare miss rates for TUC with standard CO2 for polyps and adenomas using a tandem colonoscopy design. Methods: We randomized participants to undergo tandem colonoscopies using TUC or CO2 first. In TUC, water exchange was performed during insertion, and withdrawal was performed under water. For the CO2 colonoscopy, both insertion and withdrawal were performed with CO2. The main outcomes were miss rates for polyps and adenomas for the first examination calculated as the number of additional polyps/adenomas detected during the second examination divided by the total number of polyps/adenomas detected for both examinations. Inspection times were calculated by subtracting the time for polypectomy, and care was taken to keep the times equal for both examinations. Results: A total of 121 participants were randomized with 61 having CO2 first. The overall miss rate for polyps was higher for the TUC-first group (81/237; 34%) compared with the CO2-first cohort (57/264; 22%) (P = .002). In addition, the overall miss rate for all adenomas was higher for the TUC-first group (52/146; 36%) compared with the CO2 group (37/159; 23%) (P = .025). However, 1 of the 3 endoscopists had higher polyp/adenoma miss rates for CO2, but these were not statistically significant differences. The insertion time was longer for TUC than for CO2. After adjusting for times, participant characteristics, and bowel preparation, the miss rate for polyps was higher for TUC than for CO2. Conclusions: We found that TUC had an overall higher polyp and adenoma miss rate than colonoscopy performed with CO2, and TUC took longer to perform. However, TUC may benefit some endoscopists, an issue that requires further study.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 21 条
  • [11] Impact of a novel water method on scheduled unsedated colonoscopy in US veterans
    Leung, Felix W.
    Aharonian, H. Steven
    Leung, Joseph W.
    Guth, Paul H.
    Jackson, Guy
    [J]. GASTROINTESTINAL ENDOSCOPY, 2009, 69 (03) : 546 - 550
  • [12] A randomized, controlled trial to confirm the beneficial effects of the water method on US veterans undergoing colonoscopy with the option of on-demand sedation
    Leung, Joseph
    Mann, Surinder
    Siao-Salera, Rodelei
    Ransibrahmanakul, Kanat
    Lim, Brian
    Canete, Wilhelmina
    Samson, Laramie
    Gutierrez, Rebeck
    Leung, Felix W.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2011, 73 (01) : 103 - 110
  • [13] Water Infusion for Cecal Intubation Increases Patient Tolerance, but Does Not Improve Intubation of Unsedated Colonoscopies
    Pohl, Juergen
    Messer, Insa
    Behrens, Angelika
    Kaiser, Gernot
    Mayer, Gerhard
    Ell, Christian
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2011, 9 (12) : 1039 - U134
  • [14] Warm water infusion versus air insufflation for unsedated colonoscopy: a randomized, controlled trial
    Radaelli, Franco
    Paggi, Silvia
    Amato, Arnaldo
    Terruzzi, Vittorio
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 72 (04) : 701 - 709
  • [15] Ramirez Francisco C, 2011, J Interv Gastroenterol, V1, P130
  • [16] Ramirez Francisco C, 2011, J Interv Gastroenterol, V1, P97
  • [17] Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
    Rex, DK
    Cutler, CS
    Lemmel, GT
    Rahmani, EY
    Clark, DW
    Helper, DJ
    Lehman, GA
    Mark, DG
    [J]. GASTROENTEROLOGY, 1997, 112 (01) : 24 - 28
  • [18] Colonoscopy technique in consecutive patients referred for prior incomplete colonoscopy
    Rex, Douglas K.
    Chen, Shawn C.
    Overhiser, Andrew J.
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2007, 5 (07) : 879 - 883
  • [19] Rex DK, 2016, CLIN GASTROENTEROL H, V14, P323, DOI 10.1016/j.cgh.2015.09.022
  • [20] Water Exchange vs. Water Immersion During Colonoscope Insertion
    Rex, Douglas K.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 (09) : 1401 - 1403