Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial

被引:32
作者
Huang, Jessie [1 ,2 ]
Katalinic, Paula [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Hennessy, Michael P. [1 ,3 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales Sydney, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales Sydney, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
OCULAR HYPERTENSION; REBOUND TONOMETER; RISK-FACTOR; ICARE-ONE; PROGRESSION; 24-HOUR; ACCURACY; TERM; PATTERNS;
D O I
10.1097/OPX.0000000000001172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (29) occasions for 40 (+/- 7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r(2) = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (+/- 5.2) to 16.1 (+/- 2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
[31]   Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice [J].
Cvenkel, Barbara ;
Velkovska, Makedonka Atanasovska .
CLINICAL OPHTHALMOLOGY, 2019, 13 :841-847
[32]   Risk factors of glaucoma progression: Intraocular pressure fluctuations [J].
Aptel, F. ;
Denis, P. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (06) :400-402
[33]   Clinical Audit on the Effectiveness of Clinic-Based Intraocular Pressure Phasing for Patients With Glaucoma and Glaucoma Suspect [J].
Nanthini, Selvaraja ;
Ain-Nasyrah, Ahmad Sukari ;
Omar, Raja Norliza Raja ;
Yaakub, Azhany ;
Liza-Sharmini, Ahmad Tajudin .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
[34]   Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery [J].
Lee, Sang Yeop ;
Bae, Hyoung Won ;
Kwon, Hee Jung ;
Seong, Gong Je ;
Kim, Chan Yun .
PLOS ONE, 2018, 13 (02)
[35]   Efficacy of selective laser trabeculoplasty on lowering intraocular pressure fluctuations and nocturnal peak intraocular pressure in treated primary open-angle glaucoma patients [J].
Pillunat, Karin R. ;
Kocket, Greta A. ;
Herber, Robert ;
Jasper, Carolin S. ;
Lenk, Janine ;
Pillunat, Lutz E. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (07) :1979-1985
[36]   Posture-related fluctuations of intraocular pressure in healthy children with suspicion of glaucoma [J].
Lueke, Jan Niklas ;
Enders, Philip ;
Haendel, Alexander ;
Gietzelt, Caroline ;
Dietlein, Johanna ;
Schoeneberger, Verena ;
Lappa, Alexandra ;
Widder, Randolf ;
Dietlein, Thomas S. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (01) :171-177
[37]   Comparison between Latanoprost, Travoprost, and Tafluprost in reducing intraocular pressure fluctuations in patients with glaucoma [J].
Faseeh, Ahmed Essam ;
Allam, Riham S. H. M. ;
Shalash, Ahmed B. ;
Abd Elmohsen, Mai Nasser .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) :3018-3026
[38]   The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients. [J].
Kyei, Samuel ;
Assiamah, Frank ;
Kwarteng, Michael Agyemang ;
Gboglu, Cynthia Pakyennu .
ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2020, 30 (06) :999-1004
[39]   Measurement of Intraocular Pressure by Patients With Glaucoma [J].
Pronin, Savva ;
Brown, Lyndsay ;
Megaw, Roly ;
Tatham, Andrew J. .
JAMA OPHTHALMOLOGY, 2017, 135 (10) :1030-1036
[40]   Twenty-Four-Hour Intraocular Pressure Pattern In Glaucoma Suspects in an African Population [J].
Aderounmu, Azeezat B. ;
Ademola-Popoola, Dupe S. ;
Olatunji, Fatai O. ;
Yusuf, Ibrahim A. .
JOURNAL OF GLAUCOMA, 2023, 32 (12) :1058-1063