Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial

被引:32
作者
Huang, Jessie [1 ,2 ]
Katalinic, Paula [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Hennessy, Michael P. [1 ,3 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales Sydney, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales Sydney, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
OCULAR HYPERTENSION; REBOUND TONOMETER; RISK-FACTOR; ICARE-ONE; PROGRESSION; 24-HOUR; ACCURACY; TERM; PATTERNS;
D O I
10.1097/OPX.0000000000001172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (29) occasions for 40 (+/- 7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r(2) = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (+/- 5.2) to 16.1 (+/- 2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [21] Self-monitoring of intraocular pressure in glaucoma
    Beck, Daniel
    Tatham, Andrew J.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2019, 14 (4-5) : 219 - 225
  • [22] Impact of intraocular pressure fluctuations on progression of normal tension glaucoma
    Hopf, Susanne
    Schwarauschke, Doris
    Schmidtmann, Irene
    Pfeiffer, Norbert
    Hoffmann, Esther Maria
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (10) : 1553 - 1559
  • [23] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Tan, Shaoying
    Yu, Marco
    Baig, Nafees
    Hansapinyo, Linda
    Tham, Clement C.
    SCIENTIFIC REPORTS, 2017, 7
  • [24] Self-Monitoring of Intraocular Pressure Outside of Normal Office Hours Using Rebound Tonometry: Initial Clinical Experience in Patients With Normal Tension Glaucoma
    Sood, Vaneeta
    Ramanathan, Uthaya S.
    JOURNAL OF GLAUCOMA, 2016, 25 (10) : 807 - 811
  • [25] Even-number measurement bias with Goldmann applanation tonometry in patients with glaucoma and glaucoma suspects
    Shahid, Alina
    Patel, Kosha
    Kingra, Ramanjot K.
    Rozwat, Anne S.
    Roberts, Daniel K.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (02) : 192 - 195
  • [26] Comparing the measurement of diurnal fluctuations in intraocular pressure in the same day versus over different days in glaucoma
    Magacho, Leopoldo
    Toscano, Daniela A.
    Freire, Gislene
    Shetty, Rajesh K.
    Avila, Marcos P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 542 - 545
  • [27] Intraocular Pressure According to Eye Gaze by iCare Rebound Tonometry in Normal Participants and Glaucoma Patients
    Kim, Yu Jeong
    Moon, Yeji
    Kwon, Amy M.
    Lim, Han Woong
    Lee, Won June
    JOURNAL OF GLAUCOMA, 2021, 30 (08) : 643 - 647
  • [28] Fluctuations of the Intraocular Pressure in Medically Versus Surgically Treated Glaucoma Patients by a Contact Lens Sensor
    Muniesa, Ma Jesus
    Ezpeleta, Juan
    Benitez, Ivan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 203 : 1 - 11
  • [29] Relationship Between Nocturnal Intraocular Pressure Elevation and Diurnal Intraocular Pressure Level in Normal-Tension Glaucoma Patients
    Moon, Yeji
    Lee, Jin Young
    Jeong, Da Woon
    Kim, Soa
    Han, Seungbong
    Kook, Michael S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (09) : 5271 - 5279
  • [30] Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice
    Cvenkel, Barbara
    Velkovska, Makedonka Atanasovska
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 841 - 847