Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial

被引:32
作者
Huang, Jessie [1 ,2 ]
Katalinic, Paula [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Hennessy, Michael P. [1 ,3 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales Sydney, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales Sydney, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
OCULAR HYPERTENSION; REBOUND TONOMETER; RISK-FACTOR; ICARE-ONE; PROGRESSION; 24-HOUR; ACCURACY; TERM; PATTERNS;
D O I
10.1097/OPX.0000000000001172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (29) occasions for 40 (+/- 7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r(2) = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (+/- 5.2) to 16.1 (+/- 2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
[11]   Self-tonometry in Glaucoma Management-Past, Present and Future [J].
Liang, Steve Y. -W. ;
Lee, Graham A. ;
Shields, David .
SURVEY OF OPHTHALMOLOGY, 2009, 54 (04) :450-462
[12]   SALUS-a non-inferiority trial to compare self-tonometry in glaucoma patients with regular inpatient intraocular pressure controls: study design and set-up [J].
Oldiges, Kristina ;
Steinmann, Maren ;
Duevel, Juliane Andrea ;
Gruhn, Sebastian ;
Diener, Raphael ;
Leclaire, Martin Dominik ;
Al-Nawaiseh, Sami ;
Eter, Nicole .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (12) :3945-3955
[13]   Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma [J].
Asrani, S ;
Zeimer, R ;
Wilensky, J ;
Gieser, D ;
Vitale, S ;
Lindenmuth, K .
JOURNAL OF GLAUCOMA, 2000, 9 (02) :134-142
[14]   Long-Term Reproducibility of Diurnal Intraocular Pressure Patterns in Patients with Glaucoma [J].
Aptel, Florent ;
Lesoin, Antoine ;
Chiquet, Christophe ;
Aryal-Charles, Nishal ;
Noel, Christian ;
Romanet, Jean-Paul .
OPHTHALMOLOGY, 2014, 121 (10) :1998-2003
[15]   Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients [J].
Tan, Shaoying ;
Baig, Nafees ;
Hansapinyo, Linda ;
Jhanji, Vishal ;
Wei, Shihui ;
Tham, Clement C. .
PLOS ONE, 2017, 12 (03)
[16]   Diurnal variation of intraocular pressure in suspected glaucoma patients and their outcome [J].
Tajunisah, I. ;
Reddy, S. C. ;
Fathilah, J. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) :1851-1857
[17]   Diurnal variation of intraocular pressure in suspected glaucoma patients and their outcome [J].
I. Tajunisah ;
S. C. Reddy ;
J. Fathilah .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 :1851-1857
[18]   Diurnal and Nocturnal Intraocular Pressure Fluctuations after Trabeculectomy [J].
Klink, Thomas ;
Praetorius, Stefanie ;
Leippi, Swetlana ;
Klink, Janine ;
Grehn, Franz J. .
OPHTHALMOLOGICA, 2012, 227 (03) :160-165
[19]   Use of machine learning of predict the risk of early morning intraocular pressure peaks in glaucoma patients and suspects [J].
Brandao-de-Resende, Camilo ;
Cronemberger, Sebastiao ;
Veloso, Artur W. ;
Merula, Rafael, V ;
Freitas, Carolina S. ;
Borges, Erica A. ;
Diniz-Filho, Alberto .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2021, 84 (06) :569-575
[20]   Diurnal Spikes of Intraocular Pressure in Uveitic Glaucoma: A 24-hour Intraocular Pressure Monitoring Study [J].
Esen, Fehim ;
Eraslan, Muhsin ;
Cerman, Eren ;
Celiker, Hande ;
Kazokoglu, Haluk .
SEMINARS IN OPHTHALMOLOGY, 2020, 35 (04) :246-251