Diagnostic Benefit of High b-Value Computed Diffusion-Weighted Imaging in Patients with Hepatic Metastasis

被引:10
|
作者
Ablefoni, Maxime [1 ,2 ]
Surup, Hans [2 ]
Ehrengut, Constantin [2 ]
Schindler, Aaron [3 ]
Seehofer, Daniel [4 ]
Denecke, Timm [2 ]
Meyer, Hans-Jonas [2 ]
机构
[1] Univ Leipzig, Dept Paediat Radiol, Liebigstr 20a, D-04103 Leipzig, Germany
[2] Univ Leipzig, Dept Diagnost & Intervent Radiol, Liebigstr 20, D-04103 Leipzig, Germany
[3] Univ Leipzig, Dept Hepatol, Liebigstr 20, D-04103 Leipzig, Germany
[4] Univ Leipzig, Dept Visceral Transplantat Vasc & Thorac Surg, Liebigstr 20, D-04103 Leipzig, Germany
关键词
computed diffusion-weighted imaging; high b-value; hepatic metastasis; MRI; MRI; METAANALYSIS; CANCER;
D O I
10.3390/jcm10225289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diffusion-weighted imaging (DWI) has rapidly become an essential tool for the detection of malignant liver lesions. The aim of this study was to investigate the usefulness of high b-value computed DWI (c-DWI) in comparison to standard DWI in patients with hepatic metastases. In total, 92 patients with histopathologic confirmed primary tumors with hepatic metastasis were retrospectively analyzed by two readers. DWI was obtained with b-values of 50, 400 and 800 or 1000 s/mm(2) on a 1.5 T magnetic resonance imaging (MRI) scanner. C-DWI was calculated with a monoexponential model with high b-values of 1000, 2000, 3000, 4000 and 5000 s/mm(2). All c-DWI images with high b-values were compared to the acquired DWI sequence at a b-value of 800 or 1000 s/mm(2) in terms of volume, lesion detectability and image quality. In the group of a b-value of 800 from a b-value of 2000 s/mm(2), hepatic lesion sizes were significantly smaller than on acquired DWI (metastases lesion sizes b = 800 vs. b 2000 s/mm(2): mean 25 cm(3) (range 10-60 cm(3)) vs. mean 17.5 cm(3) (range 5-35 cm(3)), p < 0.01). In the second group at a high b-value of 1500 s/mm(2), liver metastases were larger than on c-DWI at higher b-values (b = 1500 vs. b 2000 s/mm(2), mean 10 cm(3) (range 4-24 cm(3)) vs. mean 9 cm(3) (range 5-19 cm(3)), p < 0.01). In both groups, there was a clear reduction in lesion detectability at b = 2000 s/mm(2), with hepatic metastases being less visible compared to c-DWI images at b = 1500 s/mm(2) in at least 80% of all patients. Image quality dropped significantly starting from c-DWI at b = 3000 s/mm(2). In both groups, almost all high b-values images at b = 4000 s/mm(2) and 5000 s/mm(2) were not diagnostic due to poor image quality. High c-DWI b-values up to b = 1500 s/mm(2) offer comparable detectability for hepatic metastases compared to standard DWI. Higher b-value images over 2000 s/mm(2) lead to a noticeable reduction in imaging quality, which could hamper diagnosis.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Advantages of high b-value diffusion-weighted imaging to diagnose pseudo-responses in patients with recurrent glioma after bevacizumab treatment
    Yamasaki, Fumiyuki
    Kurisu, Kaoru
    Aoki, Tomokazu
    Yamanaka, Masami
    Kajiwara, Yoshinori
    Watanabe, Yosuke
    Takayasu, Takeshi
    Akiyama, Yuji
    Sugiyama, Kazuhiko
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2805 - 2810
  • [32] Potential of diffusion-weighted imaging in magnetic resonance enterography to identify neoplasms in the ileocecal region: Use of ultra-high b-value diffusion-weighted imaging
    Yu, Hao
    Feng, Cui
    Wang, Zi
    Li, Jianjun
    Wang, Yanchun
    Hu, Xuemei
    Li, Zhen
    Shen, Yaqi
    Hu, Daoyu
    ONCOLOGY LETTERS, 2019, 18 (02) : 1451 - 1457
  • [33] Hidden Infarcts Detected by a High b-Value Diffusion-Weighted Imaging: A Parameter-Optimized Study
    Song, Xiubao
    Xu, Xi
    Ye, Yufeng
    Liang, Jianye
    Ma, Mengjie
    Peng, Qiwen
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (02) : 308 - 313
  • [34] Preoperative grading of supratentorial nonenhancing gliomas by high b-value diffusion-weighted 3 T magnetic resonance imaging
    Han, Haiwei
    Han, Chengkun
    Wu, Xiurong
    Zhong, Shan
    Zhuang, Xiongjie
    Tan, Guowei
    Wu, Hua
    JOURNAL OF NEURO-ONCOLOGY, 2017, 133 (01) : 147 - 154
  • [35] Additional benefit of computed diffusion-weighted imaging for detection of hepatic metastases at 1.5 T
    Kawahara, Seiya
    Isoda, Hiroyoshi
    Fujimoto, Koji
    Shimizu, Hironori
    Furuta, Akihiro
    Arizono, Shigeki
    Ohno, Tsuyoshi
    Yamashita, Rikiya
    Ono, Ayako
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (03) : 481 - 485
  • [36] High b-value diffusion-weighted MRI for detecting gallbladder carcinoma: preliminary study and results
    Sugita, Reiji
    Yamazaki, Tetsuro
    Furuta, Akemi
    Itoh, Kei
    Fujita, Naotaka
    Takahashi, Shoki
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1794 - 1798
  • [37] Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy
    Quentin, Michael
    Schimmoeller, Lars
    Arsov, Christian
    Rabenalt, Robert
    Antoch, Gerald
    Albers, Peter
    Blondin, Dirk
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 209 - 213
  • [38] Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging
    Nakamura, Yuko
    Higaki, Toru
    Akiyama, Yuji
    Fukumoto, Wataru
    Kajiwara, Kenji
    Kaichi, Yoko
    Honda, Yukiko
    Komoto, Daisuke
    Tatsugami, Fuminari
    Iida, Makoto
    Ohmoto, Toshifumi
    Date, Shuji
    Awai, Kazuo
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 138 - 144
  • [39] Value of ultra-high b-value diffusion-weighted imaging for the evaluation of renal ischemia-reperfusion injury
    Xing, Zhaoyu
    Pan, Liang
    Yu, Anding
    Zhang, Jinggang
    Dong, Congsong
    Chen, Jie
    Xing, Wei
    He, Xiaozhou
    Zhang, Zhiping
    MAGNETIC RESONANCE IMAGING, 2024, 111 : 1 - 8
  • [40] Diffusion-weighted MR imaging of the pancreas: optimizing b-value for visualization of pancreatic adenocarcinoma
    Fukukura, Yoshihiko
    Shindo, Toshikazu
    Hakamada, Hiroto
    Takumi, Koji
    Umanodan, Tomokazu
    Nakajo, Masanori
    Kamimura, Kiyoshisa
    Umanodan, Aya
    Ideue, Junnichi
    Yoshiura, Takashi
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3419 - 3427