Extension of Golay plate height equation for open-tubular columns

被引:10
|
作者
Blumberg, Leonid M. [1 ]
机构
[1] Advachrom, POB 1243, Wilmington, DE 19801 USA
关键词
Plate height; OTC; PLOT columns; LIQUID-CHROMATOGRAPHY; THEORETICAL PLATE; STATIONARY PHASES; FILM THICKNESS; POROUS LAYER; B-TERM; DIFFUSION; EFFICIENCY; EQUIVALENT; PARTICLES;
D O I
10.1016/j.chroma.2017.10.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Golay plate height equation with its B-term equal to 2D(m)/u (Dm is molecular diffusivity of a solute in the carrier gas and u is the gas velocity) has been developed for WCOT (wall-coated open-tubular) GC columns with liquid stationary phases. In a more general case of OTC (open tubular columns) such as the PLOT (porous layer open-tubular) columns and others, the B-term is 2(D-m + kDs)/u (D-s and k are the solute net diffusivity in the stationary zone and the retention factor, respectively) which can be substantially larger than 2D(m)/u. A simple proof is provided together with other adjustments in Golay equation, and its interpretation. (C) 2017 Elsevier B.V. All.rights reserved.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [31] Polymer-brush stationary phases for open-tubular capillary electrochromatography
    Miller, MD
    Baker, GL
    Bruening, ML
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 323 - 330
  • [32] Development of an open-tubular trypsin reactor for on-line digestion of proteins
    Stigter, E. C. A.
    de Jong, G. J.
    van Bennekorn, W. P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (06) : 1967 - 1977
  • [33] Recent highlights in stationary phase design for open-tubular capillary electrochromatography
    Guihen, E
    Glennon, JD
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 67 - 81
  • [34] Multi-walled carbon nanotube composites with polyacrylate prepared for open-tubular capillary electrochromatography
    Chen, Jian-Lian
    Lu, Te-Ling
    Lin, Yi-Chen
    ELECTROPHORESIS, 2010, 31 (19) : 3217 - 3226
  • [35] Zeolite silica nanoparticles-supported open-tubular columns for isomer and chiral separation using capillary electrochromatography coupled with amperometric detection
    Zhao, Xiaoshuang
    Liu, Linzhen
    Li, Na
    Wang, Tingting
    Chai, Yuzhu
    Yang, Ziyue
    Ye, Jiannong
    Chu, Qingcui
    Chen, Li
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (03) : 1028 - 1035
  • [36] An immobilized graphene oxide stationary phase for open-tubular capillary electrochromatography
    Wang, Chun
    de Rooy, Sergio
    Lu, Cheng-Fei
    Fernand, Vivian
    Moore, Leonard, Jr.
    Berton, Paula
    Warner, Isiah M.
    ELECTROPHORESIS, 2013, 34 (08) : 1197 - 1202
  • [37] Open-tubular capillary electrochromatography using capillary columns chemically bonded with the new host molecules calix[6]crown, calix[6]arene
    Zeng, ZR
    Xie, CH
    Li, HB
    Han, HM
    Chen, YY
    ELECTROPHORESIS, 2002, 23 (09) : 1272 - 1278
  • [38] Selectivity assessment of popular stationary phases for open-tubular column gas chromatography
    Poole, CF
    Li, QL
    Kiridena, W
    Koziol, WW
    JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (01) : 107 - 117
  • [39] Open-tubular CEC with a new triethanolamine bonded stationary phase for biomolecule separation
    Aydogan, Cemil
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 976 : 27 - 32
  • [40] Kinetic optimisation of open-tubular liquid-chromatography capillaries coated with thick porous layers for increased loadability
    Causon, Tim J.
    Shellie, Robert A.
    Hilder, Emily F.
    Desmet, Gert
    Eeltink, Sebastiaan
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (46) : 8388 - 8393