摘要
Golay plate height equation with its B-term equal to 2D(m)/u (Dm is molecular diffusivity of a solute in the carrier gas and u is the gas velocity) has been developed for WCOT (wall-coated open-tubular) GC columns with liquid stationary phases. In a more general case of OTC (open tubular columns) such as the PLOT (porous layer open-tubular) columns and others, the B-term is 2(D-m + kDs)/u (D-s and k are the solute net diffusivity in the stationary zone and the retention factor, respectively) which can be substantially larger than 2D(m)/u. A simple proof is provided together with other adjustments in Golay equation, and its interpretation. (C) 2017 Elsevier B.V. All.rights reserved.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [21] Microgeometry-independent equation for measuring infinite dilution activity coefficients using gas-liquid chromatography with static-wall-coated open-tubular columns
    Xu, Qianqian
    Su, Baogen
    Bao, Zongbi
    Yang, Yiwen
    Yang, Qiwei
    Ren, Qilong
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [22] Parallel, fluorous open-tubular chromatography using microstructured fibers
    Daley, Adam B.
    Wright, Ramin D.
    Oleschuk, Richard D.
    ANALYTICA CHIMICA ACTA, 2011, 690 (02) : 253 - 262
  • [23] Accurate Measurements of Infinite Dilution Activity Coefficients Using Gas Chromatography with Static-Wall-Coated Open-Tubular Columns
    Xu, Qianqian
    Su, Baogen
    Luo, Xinyi
    Xing, Huabin
    Bao, Zongbi
    Yang, Qiwei
    Yang, Yiwen
    Ren, Qilong
    ANALYTICAL CHEMISTRY, 2012, 84 (21) : 9109 - 9115
  • [24] Immobilization of chitosan in sol-gel phases for chiral open-tubular capillary electrochromatography
    Chen, Jian-Lian
    Syu, Hong-Jie
    ANALYTICA CHIMICA ACTA, 2012, 718 : 130 - 137
  • [25] Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples
    Rogeberg, Magnus
    Vehus, Tore
    Grutle, Lene
    Greibrokk, Tyge
    Wilson, Steven Ray
    Lundanes, Elsa
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (17) : 2838 - 2847
  • [26] Application of polymeric high-internal-phase-emulsion-coated stationary-phase columns in open-tubular capillary electrochromatography
    Choudhury, Sidratul
    Connolly, Damian
    White, Blanaid
    JOURNAL OF APPLIED POLYMER SCIENCE, 2016, 133 (48)
  • [27] Selection of calibration compounds for selectivity evaluation of wall-coated, open-tubular columns for gas chromatography by the solvation parameter model
    Poole, Colin F.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1629 (1629)
  • [28] Evanescent wave-initiated photopolymerisation as a new way to create monolithic open-tubular capillary columns: use as enzymatic microreactor for on-line protein digestion
    Abele, Silvija
    Smejkal, Petr
    Yavorska, Oksana
    Foret, Frantisek
    Macka, Mirek
    ANALYST, 2010, 135 (03) : 477 - 481
  • [29] Gold nanoparticle-coated capillaries for protein and peptide analysis on open-tubular capillary electrochromatography
    Hamer, Mariana
    Yone, Angel
    Rezzano, Irene
    ELECTROPHORESIS, 2012, 33 (02) : 334 - 339
  • [30] Development of an open-tubular trypsin reactor for on-line digestion of proteins
    E. C. A. Stigter
    G. J. de Jong
    W. P. van Bennekom
    Analytical and Bioanalytical Chemistry, 2007, 389 : 1967 - 1977