Cortical bone trajectory and traditional trajectory-a radiological evaluation of screw-bone contact

被引:59
作者
Kojima, Kota [1 ,2 ]
Asamoto, Shunji [1 ]
Kobayashi, Yoshiomi [2 ]
Ishikawa, Masayuki [1 ]
Fukui, Yasuyuki [1 ]
机构
[1] Int Univ Hlth & Welf, Mita Hosp, Spine & Spinal Cord Ctr, Tokyo 1088329, Japan
[2] Keio Univ, Dept Orthoped Surg, Sch Med, Shinjuku Ku, Tokyo 1608582, Japan
关键词
Cortical bone trajectory; Screw-to-bone contact; Radiological study; CT number; Hounsfield unit; Posterior lumbar spine fusion; BIOMECHANICS;
D O I
10.1007/s00701-015-2432-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Cortical bone trajectory (CBT), a relatively new technique for pedicle screw insertion in the lumbar spine, is believed to have equivalent pullout and toggle characteristics compared with the traditional trajectory (TT). It has been hypothesized that the new trajectory offers higher cortical bone contact with the pedicle screws and therefore has an improved anchoring property over the traditional trajectory where the screws are inserted into the vertebral body trabecular space. The aim of this study is to evaluate the pedicle screw-cortical bone contact between the two trajectories from a radiological standpoint. Two hundred twenty-two patients with degenerative lumbar spine disease underwent computed tomography scanning. For each patient, axial slices of the L4 and L5 vertebra were cut in two planes, one horizontal to the pedicle representing the plane at which pedicle screws are inserted using the TT and another in a more caudo-cranial plane representing the plane at which pedicle screws are inserted using CBT. For each trajectory, a region of interest (ROI) was selected within the area in which the screws are inserted. A CT number (Hounsfield scale) was then calculated within each ROI to compare the bone density. The CT numbers within the ROI for CBT were constantly almost over four times higher than that for the TT, and there was a significant difference between the values (p < 0.0001). This study has demonstrated that, with the cortical bone trajectory, the pedicle screws penetrate a region that is richer in cortical bone compared to when using the traditional trajectory. This is in keeping with previous hypotheses that the new trajectory offers higher cortical bone contact.
引用
收藏
页码:1173 / 1178
页数:6
相关论文
共 8 条
[1]  
Asamoto S, 2013, ANN M JAP SOC SPIN S
[2]   The biomechanics of pedicle screw-based instrumentation [J].
Cho, W. ;
Cho, S. K. ;
Wu, C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1061-1065
[3]  
Crookshank M, 2014, ADV BIOMECH APPL, V1, P15
[4]   ARTICULAR TROPISM AND STABILITY OF THE LUMBAR SPINE [J].
CYRON, BM ;
HUTTON, WC .
SPINE, 1980, 5 (02) :168-172
[5]  
Gallois M., 1925, REV CHIRURG, V63, P687
[6]  
Krenz J., 1973, J BONE JOINT SURG BR, V55, P735
[7]   Biomechanics of Lumbar Cortical Screw-Rod Fixation Versus Pedicle Screw-Rod Fixation With and Without Interbody Support [J].
Perez-Orribo, Luis ;
Kalb, Samuel ;
Reyes, Phillip M. ;
Chang, Steve W. ;
Crawford, Neil R. .
SPINE, 2013, 38 (08) :635-641
[8]   Cortical bone trajectory for lumbar pedicle screws [J].
Santoni, B. G. ;
Hynes, R. A. ;
McGilvray, K. C. ;
Rodriguez-Canessa, G. ;
Lyons, A. S. ;
Henson, M. A. W. ;
Womack, W. J. ;
Puttlitz, C. M. .
SPINE JOURNAL, 2009, 9 (05) :366-373