Iohexol as a marker of glomerular filtration rate in patients with diabetes: comparison of multiple and simplified sampling protocols

被引:14
作者
Pucci, L
Bandinelli, S
Pilo, M
Nannipieri, M
Navalesi, R
Penno, G
机构
[1] Univ Pisa, Dept Endocrinol & Metab, Pisa, Italy
[2] Azienda Ospedaliera Pisana, Cisanello Hosp Pisa, Pisa, Italy
关键词
diabetes; GFR; iohexol; nephropathy; plasma clearance;
D O I
10.1046/j.1464-5491.2001.00404.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To report on the reproducibility of iohexol glomerular filtration rate (GFR) estimation, to compare the plasma clearance of iohexol with that of [Cr-51]EDTA and to evaluate the reliability of reduced sampling schedules in estimating GFR in Type 1 and Type 2 diabetes mellitus. Methods Agreement was assessed in 15 Type 1 and 26 Type 2 diabetics with creatinine ranging from 53 to 564 mmol/l. Results The regression between multiple-sample iohexol and [Cr-51]EDTA clearances was 0.999 in Type 1 and 0.987 in Type 2 diabetes (P < 0.0001 for both). A seven-sample design and the three-sample approach by Brochner-Mortensen were validated by comparison with the full-sample schedule in 87 patients (51 Type 1, 36 Type 2). Full-sample GFR was 80.3 +/- 43.8, seven-sample 79.5 +/- 43.9 (r = 0.990) and three-sample 79.8 +/- 45.2 ml.min(-1) .1.73 m(-2) (r= 0.972). The coefficients of variation of GFR were 2.7 +/- 1.4% m(-2) and 3.8 +/- 1.9% for the full-sample and the seven-sample approaches, respectively, and significantly higher for the three-sample design (6.9 +/- 3.4%, P=0.0001). Conclusions After iohexol injection, the Brochner-Mortensen schedule does not provide an accurate estimate of GFR. The seven-sample approach gives acceptable errors and allows a good estimate of GFR throughout a wide range of renal function.
引用
收藏
页码:116 / 120
页数:5
相关论文
共 18 条
[1]  
AURELL M, 1994, NEPHROL DIAL TRANSPL, V9, P1222
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[4]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[5]   Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods [J].
Chowdhury, TA ;
Dyer, PH ;
Bartlett, WA ;
Legge, ES ;
Durbin, SM ;
Barnett, AH ;
Bain, SC .
CLINICA CHIMICA ACTA, 1998, 277 (02) :153-158
[6]   MEASUREMENT OF RENAL-FUNCTION WITH IOHEXOL - A COMPARISON OF IOHEXOL, TC-99M-DTPA, AND CR-51 EDTA CLEARANCE [J].
EFFERSOE, H ;
ROSENKILDE, P ;
GROTH, S ;
JENSEN, LI ;
GOLMAN, K .
INVESTIGATIVE RADIOLOGY, 1990, 25 (07) :778-782
[7]  
FRENNBY B, 1997, SCAND J UROL NEPHROL, V31, P7
[8]  
GASPARI F, 1995, J AM SOC NEPHROL, V6, P257
[9]  
Gaspari F, 1998, J AM SOC NEPHROL, V9, P310
[10]  
GASPARI F, 1997, KIDNEY INT S, V63, pS151