Pneumatic impulsion device for microfluidic systems

被引:15
作者
Aracil, Carmen [1 ]
Quero, Jose M. [1 ]
Luque, Antonio [1 ]
Miguel Moreno, J. [1 ]
Perdigones, Francisco [1 ]
机构
[1] Univ Seville, Dpto Ingn Elect, Seville, Spain
关键词
Microfluidic device; Fluid impulsion; SU-8; PCB-MEMS; MICROELECTROMECHANICAL SYSTEMS; FABRICATION PROCESS; CIRCUIT-BOARD; SU-8; MEMS; TECHNOLOGY; VALVES;
D O I
10.1016/j.sna.2010.06.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Design, fabrication and characterization of a highly integrable fluid impulsion microdevice developed for microfluidic systems are presented in this paper. The device is composed by a chamber and a single-use microvalve that connects its output port to an external microfluidic circuit. Due to the in-plane structure, a high integration with microfluidic and electronic components can be achieved. The activation is based in the combination of mechanical to thermal phenomena. The thermal effect is producing by making an electrical current flow through a resistor, and the mechanical one by applying a differential pressure. The combination of these phenomena at the time of activation produces a reduction of the required electrical energy with respect to other devices, and also enables fluid movement. It is based on the simultaneous application of a temperature ramp that weakens the membrane and a pressure difference that provokes its collapse, bringing on also the impulsion of the fluid. The in-plane structure allows the embedding of a thermal actuator, maximizing the heat transfer to the membrane. Another significant advantage of this structure is manufacturing a series of microdevices in an array, which has been reported. As a result of the integration of SU-8 and PCB-MEMS technologies in the fabrication of the device, fully integrated microfluidic circuits can be implemented within a PCB substrate without the need of complex interfaces to external impulsion actuation. The integration also incorporates outstanding advantages as the possibility of integration with sensing and auxiliary electronics and the drastic decrement of the fabrication cost. A series of microvalves has been characterized varying their parameters of fabrication, leading to a device that requires 0.35J of electrical energy and supports a range of differential pressures from 50 to 400 kPa. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 26 条
[1]   SU-8 as a structural material for labs-on-chips and microelectromechanical systems [J].
Abgrall, Patrick ;
Conedera, Veronique ;
Camon, Henri ;
Gue, Anne-Marie ;
Nguyen, Nam-Trung .
ELECTROPHORESIS, 2007, 28 (24) :4539-4551
[2]   BETTS: bonding, exposing and transferring technique in SU-8 for microsystems fabrication [J].
Aracil, Carmen ;
Perdigones, Francisco ;
Moreno, J. Miguel ;
Quero, Jose M. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (03)
[3]   Physics and applications of microfluidics in biology [J].
Beebe, DJ ;
Mensing, GA ;
Walker, GM .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 :261-286
[4]   Development of various designs of low-power, MEMS valves for fluidic applications [J].
Cardenas-Valencia, A. M. ;
Dlutowski, J. ;
Bumgarner, J. ;
Munoz, C. ;
Wang, W. ;
Popuri, R. ;
Langebrake, L. .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 136 (01) :374-384
[5]   Fabrication process of high aspect ratio elastic and SU-8 structures for piezoelectric motor applications [J].
Dellmann, L ;
Roth, S ;
Beuret, C ;
Racine, GA ;
Lorenz, H ;
Despont, M ;
Renaud, P ;
Vettiger, P ;
de Rooij, NF .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (1-2) :42-47
[6]  
Fiedler B, 2005, INFLUENCE STRESS STA
[7]   An automated micro-solid phase extraction device involving integrated \high-pressure microvalves for genetic sample preparation [J].
Han, Song-I ;
Han, Ki-Ho ;
Frazier, A. Bruno ;
Ferrance, Jerome P. ;
Landers, James P. .
BIOMEDICAL MICRODEVICES, 2009, 11 (04) :935-942
[8]  
HEINZL J, 1985, ELECTRON */* ADV ELE, V65, P91
[9]   Processing of thin SU-8 films [J].
Keller, Stephan ;
Blagoi, Gabriela ;
Lillemose, Michael ;
Haefliger, Daniel ;
Boisen, Anja .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (12)
[10]   Single-use, thermally actuated paraffin valves for microfluidic applications [J].
Liu, RH ;
Bonanno, J ;
Yang, JN ;
Lenigk, R ;
Grodzinski, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) :328-336