Stabilization of the Atlantoaxial Joint With C1-C3 Lateral Mass Screw Constructs: Biomechanical Comparison With Standard Technique

被引:13
作者
Brasiliense, Leonardo B. C. [1 ]
Lazaro, Bruno C. R. [1 ]
Reyes, Phillip M. [1 ]
Fox, Douglas [2 ]
Sonntag, Volker K. H. [3 ]
Crawford, Neil R. [1 ]
机构
[1] St Josephs Hosp, Spinal Biomech Lab, Barrow Neurol Inst, Phoenix, AZ 85013 USA
[2] St Davids Med Ctr, NeuroTexas Inst, Austin, TX USA
[3] St Josephs Hosp, Div Neurol Surg, Barrow Neurol Inst, Phoenix, AZ 85013 USA
关键词
Altantoaxial fixation; Fusion; Vertebral artery; LAMINAR SCREWS; CERVICAL-SPINE; FIXATION; ARTHRODESIS; SUITABILITY; COMPLEX; FUSION; GRAFT; CABLE;
D O I
10.1227/NEU.0b013e3181fb414c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Anatomically and biomechanically, the atlantoaxial joint is unique compared with the remainder of the cervical spine. OBJECTIVE: To assess the in vitro stability provided by 2 C2 screw sparing techniques in a destabilized model of the atlantoaxial joint and compare with the gold standard system. METHODS: The 3-dimensional intervertebral motion of 7 human cadaveric cervical spine specimens was recorded stereophotogrammetrically while applying non-constraining, nondestructive pure moments during flexion-extension, left and right axial rotation, and left and right lateral bending. Each specimen was tested in the intact state, followed by destabilization (odontoidectomy) and fixation as follows: (1) C1 and C3 lateral mass screws rods with sublaminar wiring of C2 (LC1-C3 + SW), (2) C1 and C3 lateral mass screws rods with a cross-link in the C1-2 interlaminar space (LC1-C3 + CL), (3) C1 and C3 lateral mass screw rods alone (negative control), and (4) C1 lateral mass and C2 pedicle screws rods augmented with C1-2 interspinous wire and graft (LC1-PC2, control group). RESULTS: Compared with the intact spine, each instrumented state significantly stabilized range of motion and lax zone at C1-2 (P < .001, 1-way repeated-measures analysis of variance). LC1-C3 + SW was equivalent to LC1-PC2 during flexion and lateral bending and superior to LC1-C3 + CL during lateral bending, while LC1-C3 + CL was equivalent to LC1-PC2 only during flexion. In all other comparisons, LC1-PC2 was superior to both techniques. CONCLUSION: From a biomechanical perspective, both C2 screw sparing techniques provided sufficient stability to be regarded as an alternative for C1-2 fixation. However, because normal motion across C2-3 is sacrificed, these constructs should be used in patients with unfavorable anatomy for standard fixations.
引用
收藏
页码:ons422 / ons427
页数:6
相关论文
共 26 条
[1]   ATLANTO-AXIAL ARTHRODESIS BY WEDGE COMPRESSION METHOD [J].
BROOKS, AL ;
JENKINS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :279-284
[2]   A new technique for determining 3-D joint angles: the tilt/twist method [J].
Crawford, NR ;
Yamaguchi, GT ;
Dickman, CA .
CLINICAL BIOMECHANICS, 1999, 14 (03) :153-165
[3]   AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[4]   Construction of local vertebral coordinate systems using a digitizing probe - Technical note [J].
Crawford, NR ;
Dickman, CA .
SPINE, 1997, 22 (05) :559-563
[5]  
Crawford NR, 1998, J SPINAL DISORD, V11, P416
[6]  
Crawford NR., 2002, Seminars in Neurosurgery, V13, P101
[7]   Biomechanical characteristics of C1-2 cable fixations [J].
Dickman, CA ;
Crawford, NR ;
Paramore, CG .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :316-322
[8]   THE INTERSPINAL METHOD OF POSTERIOR ATLANTOAXIAL ARTHRODESIS [J].
DICKMAN, CA ;
SONNTAG, VKH ;
PAPADOPOULOS, SM ;
HADLEY, MN .
JOURNAL OF NEUROSURGERY, 1991, 74 (02) :190-198
[9]   Anatomic consideration of C2 pedicle screw placement [J].
Ebraheim, N ;
Rollins, JR ;
Xu, RM ;
Jackson, WT .
SPINE, 1996, 21 (06) :691-694
[10]  
Gallie W.E., 1939, Am. J. Surg, V46, P495, DOI [10.1016/S0002-9610(39)90309-0, DOI 10.1016/S0002-9610(39)90309-0]