Post-occupancy evaluation of University of Uyo buildings

被引:13
作者
Ikediashi, Dubem [1 ]
Udo, Godfrey [2 ]
Ofoegbu, Maureen [1 ]
机构
[1] Univ Uyo, Dept Bldg, Uyo, Nigeria
[2] Univ Uyo, Dept Estate Management, Uyo, Nigeria
关键词
Nigeria; Barriers; Performance evaluation; University buildings; Functional performance; Technical performance;
D O I
10.1108/JEDT-11-2019-0303
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose This study aims to evaluate the performance of buildings in the University of Uyo using the post-occupancy evaluation (POE) technique. Design/methodology/approach A quantitative questionnaire survey is adopted in which 333 copies of a validated questionnaire are administered to academic, administrative and maintenance staff and some students who occupy four buildings used for the survey. However, 124 valid responses are received giving a response rate of 37per cent. Data collected are analysed using descriptive and inferential statistical tools while the Kruskal Wallis chi-square (chi(2)) test is used to analyse hypotheses postulated for the study. Findings Findings reveal that the General Administration (GA) building has high ratings in five technical performance criteria of ambient level of sound in offices, the integrity of materials used for walls, and correctness of stair risers, threads in the building quality of lighting and quantity of lighting. Findings on the functional performance of GA building show that cleaning, friendliness, parking space, landscaping and indoor climate are the top five rated. Findings also reveal that lack of awareness about POE is a top-rated barrier, followed by a lack of orientation of stakeholders and a lack of adequately trained staff. Originality/value The study contributes to the body of knowledge on POE, particularly in universities by conducting an empirical evaluation of both technical and functional performance of the University of Uyo buildings. Besides, it establishes a set of factors that significantly hinder the implementation of POEs in universities. From a practice perspective, it provides valid feedback on which universities can build upon to improve conditions of their facilities and ultimately bolster the conducive environment for teaching and learning.
引用
收藏
页码:1711 / 1730
页数:20
相关论文
共 40 条
  • [1] Post-occupancy evaluation of postgraduate hostel facilities
    Adewunmi, Yewande
    Omirin, Modupe
    Famuyiwa, Funlola
    Fairnloye, Oluranti
    [J]. FACILITIES, 2011, 29 (3-4) : 149 - 168
  • [2] AGAGU O, 2006, THESIS
  • [3] Residential satisfaction in students' housing
    Amole, Dolapo
    [J]. JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2009, 29 (01) : 76 - 85
  • [4] [Anonymous], 2009, THESIS
  • [5] [Anonymous], 2007, THESIS
  • [6] Armijo G, 2011, GAZI U J SCI, V24, P365
  • [7] Asiabaka I P., 2008, New York Science Journal, V1, P10
  • [8] Factors affecting outsourcing decisions of maintenance services in Saudi Arabian universities
    Assaf, Sadi
    Hassanain, Mohammad A.
    Al-Hammad, Abdul-Mohsen
    Al-Nehmi, Ahmed
    [J]. PROPERTY MANAGEMENT, 2011, 29 (02) : 195 - +
  • [9] Making feedback and post-occupancy evaluation routine 1: A portfolio of feedback techniques
    Bordass, B
    Leaman, A
    [J]. BUILDING RESEARCH AND INFORMATION, 2005, 33 (04) : 347 - 352
  • [10] Critical success factors for implementation of risk assessment and management practices within the Tanzanian construction industry
    Chileshe, Nicholas
    Kikwasi, Geraldine
    [J]. ENGINEERING CONSTRUCTION AND ARCHITECTURAL MANAGEMENT, 2014, 21 (03) : 291 - +