Bone healing at non-submerged implants installed with different insertion torques: a split-mouth histomorphometric randomized controlled trial

被引:12
作者
Amari, Yoshiyuki [1 ]
Piattelli, Adriano [2 ,3 ]
Alccayhuaman, Karol Ali Apaza [1 ]
Mesa, Natalia Fortich [4 ]
Ferri, Mauro [4 ]
Iezzi, Giovanna [2 ]
Botticelli, Daniele [1 ]
机构
[1] ARDEC Acad, Ariminum Odontol, Viale Giovanni Pascoli 67, I-47923 Rimini, Italy
[2] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Chieti, Italy
[3] Catholic Univ San Antonio Murcia UCAM, Biomat Engn, Murcia, Spain
[4] Univ Corp Rafael Nunez, Program Odontol, Cartagena De Indias, Colombia
关键词
Bone-to-implant contact; Bone density; Dental implants; Histology; Histomorphometry; SUPPORTING SINGLE CROWNS; SURFACE; OSSEOINTEGRATION; STABILITY;
D O I
10.1186/s40729-019-0194-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate histomorphometrically the healing at implants installed with standard or very low insertion torque values Material and methods: Twelve volunteer patients were recruited, and two screw-shaped titanium devices were installed in the distal segments of the mandible using insertion torque values of either < 10 Ncm or similar to 30 Ncm. The implants were left to heal in a non-submerged fashion. After 8 weeks, biopsies were retrieved, and ground sections were prepared for histological evaluation. Results: Histological slides from 11 patients were available for (n = 11). The new bone in contact with the implant surface was 39.3 +/- 18.5% and 49.4 +/- 9.4% at the < 10 and similar to 30 Ncm sites, respectively. Considering the pre-existing old bone, the total mineralized bone was 46.8 +/- 22.1% at the < 10 Ncm sites and 57.0 +/- 14.1% at the similar to 30 Ncm. No statistically significant differences were found. New bone density and total mineralized bone density were 36.6 +/- 8.1% and 53.0 +/- 13.5% at the < 10 Ncm sites and 35.9 +/- 10.0% and 52.2 +/- 16.0% at the similar to 30 Ncm sites, respectively. No statistically significant differences were disclosed. Conclusion: From the data of the present study, it can be concluded that a trend of higher osseointegration was observed at the similar to 30 Ncm compared to the < 10 Ncm torque group. Nevertheless, it can be concluded that an implant installed with a very low torque may achieve a good integration.
引用
收藏
页数:9
相关论文
共 29 条
[1]  
Balshi SF, 2007, INT J ORAL MAX IMPL, V22, P467
[2]   The Effect of Insertion Torque on the Clinical Outcome of Single Implants: A Randomized Clinical Trial [J].
Barone, Antonio ;
Alfonsi, Fortunato ;
Derchi, Giacomo ;
Tonelli, Paolo ;
Toti, Paolo ;
Marchionni, Saverio ;
Covani, Ugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (03) :588-600
[3]   The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses [J].
Berardini, Marco ;
Trisi, Paolo ;
Sinjari, Bruna ;
Rutjes, Anne W. S. ;
Caputi, Sergio .
IMPLANT DENTISTRY, 2016, 25 (04) :532-540
[4]   The role of bone debris in early healing adjacent to hydrophilic and hydrophobic implant surfaces in man [J].
Bosshardt, Dieter D. ;
Salvi, Giovanni E. ;
Huynh-Ba, Guy ;
Ivanovski, Saso ;
Donos, Nikolaos ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (04) :357-364
[5]   Dynamics of osseointegration in various human and animal models - a comparative analysis [J].
Botticelli, Daniele ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (06) :742-748
[6]   Bone healing at bicortically installed implants with different surface configurations. An experimental study in rabbits [J].
Caneva, Marco ;
Lang, Niklaus P. ;
Calvo Guirado, Jose Luis ;
Spriano, Silvia ;
Iezzi, Giovanna ;
Botticelli, Daniele .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) :293-299
[7]   Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study [J].
Cesaretti, Gianfranco ;
Botticelli, Daniele ;
Renzi, Antonio ;
Rossi, Marcello ;
Rossi, Riccardo ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (04) :399-405
[8]   Effect of insertion torque on titanium implant osseointegration: an animal experimental study [J].
Duyck, Joke ;
Roesems, Rutger ;
Cardoso, Marcio V. ;
Ogawa, Toru ;
Camargos, Germana De Villa ;
Vandamme, Katleen .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) :191-196
[9]   Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque [J].
Duyck, Joke ;
Corpas, Livia ;
Vermeiren, Stephanie ;
Ogawa, Toru ;
Quirynen, Marc ;
Vandamme, Katleen ;
Jacobs, Reinhilde ;
Naert, Ignace .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) :877-884
[10]   Use of sonic instruments for implant biopsy retrieval [J].
Ferri, Mauro ;
Lang, Niklaus P. ;
Angarita Alfonso, Edwin Elias ;
Bedoya Quintero, Ivan Dario ;
Mejia Burgos, Enrique ;
Botticelli, Daniele .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (11) :1237-1243