Ventilation mode performance against airborne respiratory infections in small office spaces: limits and rational improvements for Covid-19

被引:22
作者
Pedroso Barbosa, Bruno Perazzo [1 ,3 ]
Lobo Brum, Nisio de Carvalho [2 ,3 ]
机构
[1] Fiocruz MS, Dept Architecture & Engn DAE, Av Brasil 4365, BR-21040900 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Ctr Tecnol, Dept Mech Engn, Av Horacio Macedo 2-030,Bloco G,Sala 204, BR-21941914 Rio De Janeiro, RJ, Brazil
[3] Univ Fed Rio de Janeiro, LTTC Lab Heat Transfer & Technol, Ctr Tecnol, Av Horacio Macedo 2-030,Bloco 1-2000,Sala 132, BR-21941914 Rio De Janeiro, RJ, Brazil
关键词
Covid-19; Infection control; Office; CFD; Ventilation; Airborne; PREDICTING AIR-FLOW; TURBULENCE MODELS; DISPLACEMENT VENTILATION; ENCLOSED ENVIRONMENTS; CONTAMINANT TRANSPORT; INDOOR ENVIRONMENT; CFD; TRANSMISSION; MULTIZONE; OCCUPANTS;
D O I
10.1007/s40430-021-03029-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The Coronavirus disease (Covid-19), caused by the SARS-CoV-2 virus, has produced significant social and economic disruptions in different countries. Current evidence suggests a strong correlation between the infection and the cohabitation of indoor spaces. International organizations and experts consider that the airborne transmission through aerosols can occur in specific conditions and that inadequate ventilation increases the risk of infection. As a result, the increase in ventilation rates and air filtration efficiencies are recommended for public buildings in the context of Covid-19, with significant impacts on energy consumption, and a paradigm shift in the design of ventilation systems is necessary for this new context. Therefore, this study has assessed the comparative performance of the displacement ventilation and the mixed ventilation mode on reducing the risk of long-range airborne infection for the Covid-19 in a small office application. A coupled multizone-CFD (Computational Fluid Dynamics) software developed by the National Institute of Standards and Technology was used in this study to assess the relative performance of several design solutions related to different ventilation modes, filter efficiencies, and outdoor air flow rates. The results demonstrate that the displacement ventilation technique produces a better overall performance in reducing the SARS-CoV-2 airborne infection risk than the conventional mixed ventilation for all the studied cases.
引用
收藏
页数:19
相关论文
共 82 条
[1]   Concentration, Size Distribution, and Infectivity of Airborne Particles Carrying Swine Viruses [J].
Alonso, Carmen ;
Raynor, Peter C. ;
Davies, Peter R. ;
Torremorell, Montserrat .
PLOS ONE, 2015, 10 (08)
[2]  
American National Standards Institute and American Society of Heating Refrigerating and Air-Conditioning Engineers, 2019, 6212019 ANSIAHRAE
[3]  
American National Standards Institute and American Society of Heating Refrigerating and Air-Conditioning Engineers, 2017, 5222017 ANSIASHRAE
[4]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2020, ASHRAE EP TASK FORC
[5]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2019, ASHRAE HDB APPL
[6]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2020, ASHRAE POSITION DOCU
[7]  
[Anonymous], 2020, Interim Guidance for Business and Employers
[8]  
Atkinson J, 2009, NATURAL VENTILATION FOR INFECTION CONTROL IN HEALTH-CARE SETTINGS, P1
[9]   A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects [J].
Bivolarova, M. ;
Ondracek, J. ;
Melikov, A. ;
Zdimal, V. .
INDOOR AIR, 2017, 27 (06) :1201-1212
[10]   Exposure of health care workers and occupants to coughed airborne pathogens in a double-bed hospital patient room with overhead mixing ventilation [J].
Bolashikov, Zhecho D. ;
Melikov, Arsen K. ;
Kierat, Wojciech ;
Popiolek, Zbigniew ;
Brand, Marek .
HVAC&R RESEARCH, 2012, 18 (04) :602-615