Dynamic assessment of the tear film muco-aqueous and lipid layers using a novel tear film imager (TFI)

被引:18
作者
Segev, Fani [1 ,2 ]
Geffen, Noa [1 ,2 ]
Galor, Anat [3 ,4 ]
Cohen, Yoel [5 ]
Gefen, Raanan [5 ]
Belkin, Avner [1 ]
Arieli, Yoel [5 ,6 ]
Epshtein, Shlomi [5 ]
Oren, Anat [2 ]
Harris, Alon [7 ]
机构
[1] Meir Med Ctr, Ophthalmol, Kefar Sava, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Dept Ophthalmol, Tel Aviv, Israel
[3] Miami VA Med Ctr, Ophthalmol, Miami, FL 33125 USA
[4] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
[5] AdOM Adv Opt Technol, R&D Dept, Lod, Israel
[6] Jerusalem Coll Technol, Dept Appl Phys, Jerusalem, Israel
[7] Indiana Univ Sch Med, Dept Ophthalmol, Indianapolis, IN 46202 USA
关键词
dry eye; tear film; imaging; tear breakup; technology; PRECORNEAL; THICKNESS; DISEASE;
D O I
10.1136/bjophthalmol-2018-313379
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The objective of the study was to assess a new technology, the tear film imager (TFI), which can dynamically image the muco-aqueous and lipid layers. Methods Prospective pilot case series of individuals with and without dry eye (DE). Two sequential images were obtained with the TFI. Measurements were assessed for reproducibility and compared with clinically derived DE metrics. Individuals were grouped into DE categories based on signs of DE. Results 49 patients participated in the study with a mean age of 58.8 years (SD 15.9) and a female majority (69%). Reproducibility of the muco-aqueous layer thickness (MALT) was excellent (r=0.88). MALT measurements significantly correlated with the Schirmer score (r=0.31). Lipid break up time (LBUT) as measured by the TFI significantly correlated with the clinical measure of tear break up time (TBUT) (r=0.73). MALT and LBUT were significantly thinner and shorter, respectively, in the DE groups (mild-moderate and severe) compared with the control group. When comparing TFI parameters to clinically assessed signs, sensitivity of the device was 87% and specificity was 88%. Conclusion The TFI is the first machine capable of reproducibly measuring muco-aqueous thickness in human subjects which correlates with Schirmer score. In parallel, it assesses other important aspects of tear film function which correlate with clinician assessed DE metrics.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 15 条
[1]   TFOS DEWS II pathophysiology report [J].
Bron, Anthony J. ;
de Paiva, Cintia S. ;
Chauhan, Sunil K. ;
Bonini, Stefano ;
Gabison, Eric E. ;
Jain, Sandeep ;
Knop, Erich ;
Markoulli, Maria ;
Ogawa, Yoko ;
Perez, Victor ;
Uchino, Yuichi ;
Yokoi, Norihiko ;
Zoukhri, Driss ;
Sullivan, David A. .
OCULAR SURFACE, 2017, 15 (03) :438-510
[2]  
Bron AJ, 2014, OCUL SURF, V12, pS1, DOI 10.1016/j.jtos.2014.02.002
[3]   Agreement between Automated and Traditional Measures of Tear Film Breakup [J].
Cox, Stephanie M. ;
Nichols, Kelly K. ;
Nichols, Jason J. .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (09) :E257-E263
[4]   TFOS DEWS II Definition and Classification Report [J].
Craig, Jennifer P. ;
Nichols, Kelly K. ;
Akpek, Esen K. ;
Caffery, Barbara ;
Dua, Harminder S. ;
Joo, Choun-Ki ;
Liu, Zuguo ;
Nelson, J. Daniel ;
Nichols, Jason J. ;
Tsubota, Kazuo ;
Stapleton, Fiona .
OCULAR SURFACE, 2017, 15 (03) :276-283
[5]   Visualization of the Precorneal Tear Film Using Ultrahigh Resolution Optical Coherence Tomography in Dry Eye [J].
Cui, Lele ;
Wang, Jianhua ;
Perez, Victor L. ;
Shen, Meixiao ;
Yuan, Yimin ;
Wang, Michael R. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (04) :240-244
[6]   Analysis of Factors Associated With the Tear Film Lipid Layer Thickness in Normal Eyes and Patients With Dry Eye Syndrome [J].
Jung, Ji Won ;
Park, Si Yoon ;
Kim, Jin Sun ;
Kim, Eung Kweon ;
Seo, Kyoung Yul ;
Kim, Tae-im .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (10) :4076-4083
[7]   Application of a Novel Interferometric Method to Investigate the Relation between Lipid Layer Thickness and Tear Film Thinning [J].
King-Smith, P. Ewen ;
Hinel, Erich A. ;
Nichols, Jason J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) :2418-2423
[8]  
King-Smith PE, 2000, INVEST OPHTH VIS SCI, V41, P3348
[9]   A Simple Novel Technique of Infrared Meibography by Means of Spectral-Domain Optical Coherence Tomography: A Cross-Sectional Clinical Study [J].
Napoli, Pietro Emanuele ;
Coronella, Franco ;
Satta, Giovanni Maria ;
Iovino, Claudio ;
Sanna, Raffaele ;
Fossarello, Maurizio .
PLOS ONE, 2016, 11 (10)
[10]   Evaluation of the Adhesive Properties of the Cornea by Means of Optical Coherence Tomography in Patients with Meibomian Gland Dysfunction and Lacrimal Tear Deficiency [J].
Napoli, Pietro Emanuele ;
Coronella, Franco ;
Satta, Giovanni Maria ;
Galantuomo, Maria Silvana ;
Fossarello, Maurizio .
PLOS ONE, 2014, 9 (12)