Femoral head diameter considerations for primary total hip arthroplasty

被引:45
作者
Girard, J. [1 ]
机构
[1] Ctr Hosp Reg Univ CHRU Lille, Fac Med Lille 2, Serv Orthopedie Domaine Med & Sport C, F-59037 Lille, France
关键词
Dislocation; Large-diameter femoral head; Hip resurfacing; Aseptic loosening; RESURFACING ARTHROPLASTY; GROIN PAIN; REPLACEMENT; DISLOCATION; MOTION; RANGE; BIOMECHANICS; COMPONENTS; BEARINGS; IMPLANTS;
D O I
10.1016/j.otsr.2014.07.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The configuration of total hip arthroplasty (THA) implants has constantly evolved since they were first introduced. One of the key components of THA design is the diameter of the prosthetic femoral head. It has been well established that the risk of dislocation is lower as the head diameter increases. But head diameter impacts other variables beyond joint stability: wear, cam-type impingement, range of motion, restoration of biomechanics, proprioception and groin pain. The introduction of highly crosslinked polyethylene and hard-on-hard bearings has allowed surgeons to implant large-diameter heads that almost completely eliminate the risk of dislocation. But as a result, cup liners have become thinner. With femoral head diameters up to 36 mm, the improvement in joint range of motion, delay in camtype impingement and reduction in dislocation risk have been clearly demonstrated. Conversely, large-diameter heads do not provide any additional improvements. If an "ecologically sound" approach to hip replacement is embraced (e.g. keeping the native femoral head diameter), hip resurfacing with a metal-on-metal bearing must be carried out. The reliability of large-diameter femoral heads in the longer term is questionable. Large-diameter ceramic-on-ceramic bearings may be plagued by the same problems as metal-on-metal bearings: groin pain, squeaking, increased stiffness, irregular lubrication, acetabular loosening and notable friction at the Morse taper. These possibilities require us to be extra careful when using femoral heads with a diameter greater than 36 mm. (C) 2014 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S25 / S29
页数:5
相关论文
共 38 条
[1]   Alumina-on-alumina hip implants A WEAR STUDY OF RETRIEVED COMPONENTS [J].
Affatato, S. ;
Traina, F. ;
De Fine, M. ;
Carmignato, S. ;
Toni, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01) :37-42
[2]   Do Larger Femoral Heads Improve the Functional Outcome in Total Hip Arthroplasty? [J].
Allen, Charlotte L. ;
Hooper, Gary J. ;
Frampton, Christopher M. A. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (02) :401-404
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]   The Prevalence of Groin Pain After Metal-on-Metal Total Hip Arthroplasty and Total Hip Resurfacing [J].
Bartelt, Robert B. ;
Yuan, Brandon J. ;
Trousdale, Robert T. ;
Sierra, Rafael J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2346-2356
[5]   Incidence of Groin Pain After Metal-on-Metal Hip Resurfacing [J].
Bin Nasser, Ahmad ;
Beaule, Paul E. ;
O'Neill, Michelle ;
Kim, Paul R. ;
Fazekas, Anna .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :392-399
[6]   High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication [J].
Bishop, Nicholas E. ;
Hothan, Arne ;
Morlock, Michael M. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (05) :807-813
[7]   Biomechanics of short hip endoprostheses - The risk of bone failure increases with decreasing implant size [J].
Bishop, Nicholas E. ;
Burton, Andrew ;
Maheson, Marci ;
Morlock, Michael M. .
CLINICAL BIOMECHANICS, 2010, 25 (07) :666-674
[8]  
Bonnaig Nicolas S, 2011, Orthopedics, V34, P132, DOI 10.3928/01477447-20101221-36
[9]   Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing [J].
Bouffard, Vicky ;
Nantel, Julie ;
Therrien, Marc ;
Vendittoli, Pascal-Andre ;
Lavigne, Martin ;
Prince, Francois .
REHABILITATION RESEARCH AND PRACTICE, 2011, 2011
[10]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19