One-tube real-time isothermal amplification assay to identify and distinguish human immunodeficiency virus type 1 subtypes A, B, and C and circulating recombinant forms AE and AG

被引:36
|
作者
de Baar, MP
Timmer, EC
Bakker, M
de Rooij, E
van Gemen, B
Goudsmit, J
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Human Retrovirol, NL-1105 AZ Amsterdam, Netherlands
[2] PrimaGen, Amsterdam, Netherlands
[3] Amsterdam Inst Viral Genom, Amsterdam, Netherlands
关键词
D O I
10.1128/JCM.39.5.1895-1902.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To halt the human immunodeficiency virus type 1 (HIV-1) epidemic requires interventions that can prevent transmission of numerous HTV-1 subtypes. The most frequently transmitted viruses belong to the subtypes A, B, and C and the circulating recombinant forms (CRFs) AE and AG. A fast one-tube assay that identifies and distinguishes among subtypes A, B, and C and CRFs AE and AG of HIV-1 was developed. The assay amplifies a part of the gag gene sequence of the genome of all currently known HIV-1 subtypes and can identify and distinguish among the targeted subtypes as the reaction proceeds, because of the addition of subtype-specific molecular beacons with multiple fluorophores. The combination of isothermal nucleic acid sequence-based amplification and molecular beacons is a new approach in the design of real-time assays. To obtain a sufficiently specific assay, we developed a new strategy in the design of molecular beacons, purposely introducing mismatches in the molecular beacons. The subtype A and CRF AG isolates reacted with the same molecular beacon. We tested the specificity and sensitivity of the assay on a panel of the culture supernatant of 34 viruses encompassing all HIV-1 subtypes: subtypes A through G, CRF AE and AG, a group O isolate, and a group N isolate, Assay sensitivity on this panel was 92%, with 89% correct subtype identification relative to sequence analysis. A linear relationship was found between the amount of input RNA in the reaction mixture and the time that the reaction became positive. The lower detection level of the assay was approximately 10(3) copies of HIV-1. RNA per reaction. In 38% of 50 serum samples from EW-l-infected individuals with a detectable amount of virus, we could identify subtype sequences with a specificity of 94% by using sequencing and phylogenetic analysis as the "gold standard." In conclusion, we showed the feasibility of the approach of using multiple molecular beacons labeled with different fluorophores in combination with isothermal amplification to identify and distinguish subtypes A, B, and C and CRFs AE and AG of HIV-1. Because of the low sensitivity, the assay in this format would not be suited far clinical use but can possibly be used for epidemiological monitoring as well as vaccine research studies.
引用
收藏
页码:1895 / 1902
页数:8
相关论文
共 43 条
  • [31] Clinical performance of an in-house real-time RT-PCR assay using a fluorogenic LUX™ primer for quantitation of human immunodeficiency virus type-1 (HIV-1)
    Rekhviashvili, Natela
    Stevens, Wendy
    Marinda, Edmore
    Gonin, Rene
    Stevens, Gwynneth
    McIntyre, James
    Wood, Robin
    JOURNAL OF VIROLOGICAL METHODS, 2007, 146 (1-2) : 14 - 21
  • [32] A novel TaqMan real-time PCR assay to estimate ex vivo human immunodeficiency virus type 1 fitness in the era of multi-target (pol and env) antiretroviral therapy
    Weber, J
    Rangel, HR
    Chakraborty, B
    Tadele, M
    Martinez, MA
    Martinez-Picado, J
    Marotta, ML
    Mirza, M
    Ruiz, L
    Clotet, B
    Wrin, T
    Petropoulos, CJ
    Quiñones-Mateu, ME
    JOURNAL OF GENERAL VIROLOGY, 2003, 84 : 2217 - 2228
  • [33] Spatio-temporal distribution analysis of circulating genotypes of dengue virus type 1 in western and southern states of India by a one-step real-time RT-PCR assay
    Alagarasu, K.
    Patil, J. A.
    Kakade, M. B.
    More, A. M.
    Bote, M.
    Chowdhury, D.
    Seervi, M.
    Rajesh, N. T.
    Ashok, M.
    Anukumar, B.
    Abraham, A. M.
    Parashar, D.
    Shah, P. S.
    INFECTION GENETICS AND EVOLUTION, 2019, 75
  • [34] Clinical Evaluation of a Low Cost, In-House Developed Real-Time RT-PCR Human Immunodeficiency Virus Type 1 (HIV-1) Quantitation Assay for HIV-1 Infected Patients
    Kaur, Palvinder
    Khong, Wei Xin
    Wee, Sue Yuen
    Tan, Eng Lee
    Pipper, Juergen
    Koay, Evelyn
    Kah Ying Ng
    Yap, Joe Kwan
    Chew, Kuan Kiat
    Tan, Mei Ting
    Leo, Yee Sin
    Inoue, Masafumi
    Oon Tek Ng
    PLOS ONE, 2014, 9 (03):
  • [35] Comparative evaluation of the performance of the Abbott real-time human immunodeficiency virus type I (HIV-1) assay for measurement of HIV-1 plasma viral load following automated specimen preparation
    Garcia-Diaz, A.
    Clewley, G. S.
    Booth, C. L.
    Labett, W.
    McAllister, N.
    Geretti, A. M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (05) : 1788 - 1791
  • [36] Development and clinical validation of a one-step pentaplex real-time reverse transcription PCR assay for detection of hepatitis virus B, C, E, Treponema pallidum, and a human housekeeping gene
    Li, Miaomiao
    Lv, Yan
    Cui, Dawei
    Xu, Yushan
    Lin, Mengjiao
    Zhang, Xiaojun
    Wang, Yongjun
    Shen, Cuifen
    Xie, Jue
    BMC INFECTIOUS DISEASES, 2023, 23 (01)
  • [37] Development and clinical validation of a one-step pentaplex real-time reverse transcription PCR assay for detection of hepatitis virus B, C, E, Treponema pallidum, and a human housekeeping gene
    Miaomiao Li
    Yan Lv
    Dawei Cui
    Yushan Xu
    Mengjiao Lin
    Xiaojun Zhang
    Yongjun Wang
    Cuifen Shen
    Jue Xie
    BMC Infectious Diseases, 23
  • [38] Biologic and genetic characterization of a panel of 60 human immunodeficiency virus type 1 isolates, representing clades A, B, C, D, CRF01_AE, and CRF02_AG, for the development and assessment of candidate vaccines
    Brown, BK
    Darden, JM
    Tovanabutra, S
    Oblander, T
    Frost, J
    Sanders-Buell, E
    de Souza, MS
    Birx, DL
    McCutchan, FE
    Polonis, VR
    JOURNAL OF VIROLOGY, 2005, 79 (10) : 6089 - 6101
  • [39] Performance of a Novel Human Immunodeficiency Virus (HIV) Type 1 Total Nucleic Acid-Based Real-Time PCR Assay Using Whole Blood and Dried Blood Spots for Diagnosis of HIV in Infants
    Stevens, Wendy
    Erasmus, Linda
    Moloi, Matsidisho
    Taleng, Thabo
    Sarang, Somaya
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (12) : 3941 - 3945
  • [40] Single-Point Mutations Causing More than 100-Fold Underestimation of Human Immunodeficiency Virus Type 1 (HIV-1) Load with the Cobas TaqMan HIV-1 Real-Time PCR Assay
    Korn, Klaus
    Weissbrich, Benedikt
    Henke-Gendo, Cornelia
    Heim, Albert
    Jauer, Christin Mariel
    Taylor, Ninon
    Eberle, Josef
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 1238 - 1240