An evaluation of automated neonatal seizure detection methods

被引:74
作者
Faul, S [1 ]
Boylan, G
Connolly, S
Marnane, L
Lightbody, G
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Elect & Elect Engn, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Dept Pediat & Child Hlth, Cork, Ireland
[3] St Vincents Univ Hosp, Dept Clin Neurophysiol, Dublin, Ireland
关键词
EEG; seizure detection; neonatal seizure; automated detection; Fourier analysis; EEG modelling;
D O I
10.1016/j.clinph.2005.03.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To evaluate 3 published automated algorithms for detecting seizures in neonatal EEG. Methods: One-minute, artifact-free EEG segments consisting of either EEG seizure activity or non-seizure EEG activity were extracted from EEG recordings of 13 neonates. Three published neonatal seizure detection algorithms were tested on each EEG recording. In an attempt to obtain improved detection rates, threshold values in each algorithm were manipulated and the actual algorithms were altered. Results: We tested 43 data files containing seizure activity and 34 data files free from seizure activity. The best results for Gotman, Liu and Celka, respectively, were as follows: sensitivities of 62.5, 42.9 and 66.1% along with specificities of 64.0, 90.2 and 56.0%. Conclusions: The levels of performance achieved by the seizure detection algorithms are not high enough for use in a clinical environment. The algorithm performance figures for our data set are considerably worse than those quoted in the original algorithm source papers. The overlap of frequency characteristics of seizure and non-seizure EEG, artifacts and natural variances in the neonatal EEG cause a great problem to the seizure detection algorithms. Significance: This study shows the difficulties involved in detecting seizures in neonates and the lack of a reliable detection scheme for clinical use. It is clear from this study that while each algorithm does produce some meaningful information, the information would only be usable in a reliable neonatal seizure detection process when accompanied by more complex analysis, and more advanced classifiers. (c) 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1533 / 1541
页数:9
相关论文
共 19 条
  • [1] THE ANALYSIS OF OBSERVED CHAOTIC DATA IN PHYSICAL SYSTEMS
    ABARBANEL, HDI
    BROWN, R
    SIDOROWICH, JJ
    TSIMRING, LS
    [J]. REVIEWS OF MODERN PHYSICS, 1993, 65 (04) : 1331 - 1392
  • [2] Permutation entropy: A natural complexity measure for time series
    Bandt, C
    Pompe, B
    [J]. PHYSICAL REVIEW LETTERS, 2002, 88 (17) : 4
  • [3] BARRON A, 1998, IEEE T INF THEORY, V44
  • [4] CELKA P, 2002, IEEE T BIOMED ENG, V49
  • [5] THE EXACT ICTAL AND INTERICTAL DURATION OF ELECTROENCEPHALOGRAPHIC NEONATAL SEIZURES
    CLANCY, RR
    LEGIDO, A
    [J]. EPILEPSIA, 1987, 28 (05) : 537 - 541
  • [6] DASILVA FHL, 1974, KYBERNETIK, V15, P27, DOI DOI 10.1007/BF00270757
  • [7] EVANS DH, 2000, DOPPLER ULTRASOUND
  • [8] EXIL G, 1995, EPILEPSIA, V36, P528
  • [9] FAUL S, 2004, P IRISH SIGN SYST C, P428
  • [10] Automatic seizure detection in the newborn: methods and initial evaluation
    Gotman, J
    Flanagan, D
    Zhang, J
    Rosenblatt, B
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (03): : 356 - 362