Chitosan-diaphragm based optical-fiber hydrophone for in-vivo ultrasound measurements

被引:0
|
作者
Chen, L. H. [1 ]
Chan, C. C. [1 ]
Ang, X. M. [1 ]
Leong, K. C. [2 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, 70 Nanyang Dr, Singapore 637457, Singapore
[2] GLOBALFOUNDRIES SINGAPORE PTE LTD, Singapore, Singapore
来源
ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV | 2010年 / 7853卷
关键词
D O I
10.1117/12.870188
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
The purpose of this work is the development of a high sensitivity and biocompatibility Fiber-Optic hydrophone for in-vivo ultrasound measurements. The selected sensing element-chitosan diaphragm allows matched-load condition due to its relatively permeable property. Chitosan is a natural polysaccharide which considered as biocompatible and biodegradable material that can be safe in performing the in-vivo measurement. The configuration of the sensor is based on the fiber-optic Fabry-Perot interferometry which offers good spatial resolution in the tens of MHz range [1] and robust response. Significant applications of the proposed sensor are in vivo micro-imaging [2], in-vivo lithotripsy measurement [3] or event the laboratory characterization of medical ultrasound sources. In this paper, the performance of the sensor is characterized by comparison with a PVDF needle hydrophone in term of sensitivity, frequency response and directivity.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Minimal-invasive fiber probes for optical in-vivo oxygen measurements with integrated optical thermometer
    Loehmannsroeben, Hans-Gerd
    Schmaelzlin, Elmar
    FIBER OPTIC SENSORS AND APPLICATIONS V, 2007, 6770 : V7700 - V7700
  • [22] AN OPTICAL-FIBER RING INTERFACE BUS FOR PRECISE ELECTRICAL MEASUREMENTS
    ROBINSON, IA
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (10) : 949 - 956
  • [23] ENZYME-BASED OPTICAL-FIBER BIOSENSORS
    MASCINI, M
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) : 121 - 125
  • [24] NONDESTRUCTIVE DISPERSION-ZERO MEASUREMENTS ALONG AN OPTICAL-FIBER
    JOPSON, RM
    EISELT, M
    STOLEN, RH
    DEROSIER, RM
    VENGSARKAR, AM
    KOREN, U
    ELECTRONICS LETTERS, 1995, 31 (24) : 2115 - 2117
  • [25] Implementation of Optical-Fiber Postmortem Dose Measurements: A Proof of Concept
    Di Francesca, Diego
    Kandemir, Keziban
    Li Vecchi, Gaetano
    Alia, Ruben Garcia
    Kadi, Yacine
    Brugger, Markus
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (01) : 140 - 145
  • [26] Optical Fiber Hydrophone Based on Distributed Acoustic Sensing
    Yang, Yang
    Xu, Tuanwei
    Feng, Shengwen
    Huang, Jianfen
    Li, Fang
    FIBER OPTIC SENSING AND OPTICAL COMMUNICATION, 2018, 10849
  • [27] Optical implement of optical-fiber network based on polarization and optical activity
    Zhang, HY
    Feng, XY
    OPTICAL INTERCONNECTS FOR TELECOMMUNICATION AND DATA COMMUNICATIONS, 2000, 4225 : 228 - 232
  • [28] An optimized design of a fiber optic hydrophone based on a flat diaphragm and multilayer fiber coils: A theoretical approach
    Zhang, Wentao
    Liu, Yuliang
    Li, Fang
    MEASUREMENT, 2009, 42 (02) : 171 - 174
  • [29] ABSORPTION-BASED OPTICAL-FIBER OXYGEN SENSOR
    BALDINI, F
    BACCI, M
    COSI, F
    DELBIANCO, A
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) : 752 - 757
  • [30] OPTICAL-FIBER ACCELEROMETER BASED ON A SILICON MICROMACHINED CANTILEVER
    MALKI, A
    LECOY, P
    MARTY, J
    RENOUF, C
    FERDINAND, P
    APPLIED OPTICS, 1995, 34 (34): : 8014 - 8018