Experimental and numerical investigation on shell-and-tube exhaust gas recirculation cooler with different tube bundles

被引:16
作者
Liu, Lin [1 ]
Shen, Tong [1 ]
Zhang, Lin [1 ]
Peng, Hao [2 ]
Zhang, Suolong [1 ]
Xu, Weigang [1 ]
Bo, Shi [1 ]
Qu, Songzheng [1 ]
Ni, Xiaomeng [1 ]
机构
[1] Changzhou Univ, Sch Mech Engn, Jiangsu Key Lab Green Proc Equipment, 1 Ge Hu Rd, Changzhou 213164, Peoples R China
[2] Nanjing Tech Univ, Jiangsu Key Lab Proc Enhancement & New Energy Equ, Sch Mech & Power Engn, 30 Pu Zhu South Rd, Nanjing 211816, Peoples R China
基金
中国国家自然科学基金;
关键词
HEAT-TRANSFER CHARACTERISTICS; INTERNALLY FINNED TUBE; TRANSFER PERFORMANCE; TURBULENT-FLOW; EXCHANGERS; FINS; OPTIMIZATION; HOLE;
D O I
10.1007/s00231-019-02721-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer characteristics of shell-and-tube exhaust gas recirculation (EGR) coolers with different tube bundles were studied by experiment and numerical simulation. The overall heat transfer coefficient and shell-side pressure drop were determined. The influences of tube spacing, baffle form, baffle arrangement and number on the overall heat transfer coefficient and shell-side pressure drop were investigated. The maximum differences between the numerical and experimental results are approximately 4.1% for overall heat transfer coefficient and 3.3% for shell-side pressure drop, respectively. The results indicate that the overall heat transfer coefficient of EGR cooler with wave fin arrays internally finned tubes is 1.3~1.7 times than that of EGR cooler with longitudinal plate-rectangle internally finned tubes. And the comprehensive heat performance is more reasonable when tube spacing and baffle number are equal to 12 mm and 9, respectively. It is confirmed that the trisection ellipse helical baffle is superior to the segmental baffle, but the influence of improving overall thermal performance by setting baffles is limited for small EGR cooler.
引用
收藏
页码:601 / 615
页数:15
相关论文
共 30 条
[1]   Characteristics of forced convection heat transfer in vertical internally finned tube [J].
Al-Sarkhi, A ;
Abu-Nada, E .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2005, 32 (3-4) :557-564
[2]   Numerical investigation on effects of using segmented and helical tube fins on thermal performance and efficiency of a shell and tube heat exchanger [J].
Amini, Reza ;
Amini, Mohsen ;
Jafarinia, Alireza ;
Kashfi, Mehdi .
APPLIED THERMAL ENGINEERING, 2018, 138 :750-760
[3]   Thermal enhancement of parabolic trough collector with internally finned absorbers [J].
Bellos, Evangelos ;
Tzivanidis, Christos ;
Tsimpoukis, Dimitrios .
SOLAR ENERGY, 2017, 157 :514-531
[4]  
Bichkar P., 2018, PROCEDIA MANUF, V20, P195, DOI DOI 10.1016/J.PROMFG.2018.02.028
[5]   Impact of helical baffle structure on heat transfer performance of vertical condensers [J].
Chen, Yaping ;
Yang, Shifan ;
Wu, Jiafeng ;
Zhou, Jiahao .
APPLIED THERMAL ENGINEERING, 2017, 115 :9-16
[6]   Flow and heat transfer characteristics of a double-tube structure internal finned tube with blossom shape internal fins [J].
Duan, Luanfang ;
Ling, Xiang ;
Peng, Hao .
APPLIED THERMAL ENGINEERING, 2018, 128 :1102-1115
[7]   Numerical comparison of shell-side performance for shell and tube heat exchangers with trefoil-hole, helical and segmental baffles [J].
El Maakoul, Anas ;
Laknizi, Azzedine ;
Saadeddine, Said ;
El Metoui, Mustapha ;
Zaite, Abdelkabir ;
Meziane, Mohamed ;
Ben Abdellah, Abdelatif .
APPLIED THERMAL ENGINEERING, 2016, 109 :175-185
[8]   Heat transfer optimization in internally finned tubes under laminar flow conditions [J].
Fabbri, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (10) :1243-1253
[9]   Numerical investigation of the effects of fin shape, antifreeze and nanoparticles on the performance of compact finned-tube heat exchangers for automobile radiator [J].
Habibian, S. H. ;
Abolmaali, Ali Mostafazade ;
Afshin, H. .
APPLIED THERMAL ENGINEERING, 2018, 133 :248-260
[10]   Thermal optimization of internally finned tube with variable fin thickness [J].
Kim, Dong-Kwon .
APPLIED THERMAL ENGINEERING, 2016, 102 :1250-1261