On-field monitoring of the magnetic axis misalignment in multi-coils solenoids

被引:3
作者
Arpaia, P. [1 ,2 ]
De Vito, L. [2 ,3 ]
Esposito, A. [1 ,4 ]
Parrella, A. [1 ,5 ]
Vannozzi, A. [6 ]
机构
[1] Univ Naples Federico II, Dept Elect Engn & Informat Technol, Instrumentat & Measurement Particle Accelerators, Naples, Italy
[2] Natl Inst Nucl Phys INFN, Naples, Italy
[3] Univ Sannio, Dept Engn, Benevento, Italy
[4] Politecn Torino, Dept Elect & Telecommun, Turin, Italy
[5] Univ Lisbon, Inst Super Tecn, Lisbon, Portugal
[6] Natl Inst Nucl Phys, Accelerator Div Magnets & Power Supplies INFN LNF, Rome, Italy
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
关键词
Instrumentation for FEL; Instrumentation for particle accelerators and storage rings - low energy (linear accelerators; cyclotrons; electrostatic accelerators); Instrumentation for particle-beam therapy;
D O I
10.1088/1748-0221/13/08/P08017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method for monitoring the coils alignment in multi-coil magnets, directly during their operation in particle accelerators, is proposed. Few measures of the magnetic field by Hall transducers and a local field model allows one to monitor the magnetic axis position of each coil. Thus, the particle beam can be kept strongly focused over its operation time by means of feedback. Furthermore, the uncertainty in measuring the magnetic axis was studied with the aim of finding the optimal placing of the transducers, where the minimum uncertainty is achieved. The method was validated on a challenging case study on the European project "ELI Nuclear Physics" (ELI-NP). In particular, simulations results, based on both analytical and finite-element models of the ELI-NP multi-coil solenoid, point to an uncertainty below 100 mu m, for misalignment of the magnetic axes in rotation up to pi / 1000 and in translation of 1/1000 times the length of a single coil. This uncertainty is limited by the Hall transducers technology, but has potential for large improvement margins, because the measurement model error is below 1 mu m.
引用
收藏
页数:14
相关论文
共 20 条
[1]  
[Anonymous], 2008, Evaluation of measurement data - Guide to the expression of uncertainty in measurement
[2]   HINS Linac Front End Focusing System R&D [J].
Apollinari, Giorgio ;
Carcagno, Ruben H. ;
Dimarco, Joseph ;
Huang, Yuenian ;
Kashikhin, Vadim V. ;
Orris, Darryl F. ;
Page, Thomas M. ;
Rabehl, Roger R. ;
Sylvester, Cosmore ;
Tartaglia, Michael A. ;
Terechkine, Iouri ;
Tompkins, John C. ;
Mustapha, Brahim ;
Ostroumov, Peter .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :1368-1371
[3]   Proof-of-principle demonstration of a translating coils-based method for measuring the magnetic field of axially-symmetric magnets [J].
Arpaia, P. ;
Buzio, M. ;
Kazazi, M. ;
Russenschuck, S. .
JOURNAL OF INSTRUMENTATION, 2015, 10
[4]   Vibrating-wire measurement method for centering and alignment of solenoids [J].
Arpaia, P. ;
Petrone, C. ;
Russenschuck, S. ;
Walckiers, L. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[5]   Measuring field multipoles in accelerator magnets with small-apertures by an oscillating wire moved on a circular trajectory [J].
Arpaia, P. ;
Buzio, M. ;
Perez, J. Garcia ;
Petrone, C. ;
Russenschuck, S. ;
Walckiers, L. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[6]   Measuring the magnetic axis alignment during solenoids working [J].
Arpaia, Pasquale ;
Celano, Biase ;
De Vito, Luca ;
Esposito, Antonio ;
Parrella, Alessandro ;
Vannozzi, Alessandro .
SCIENTIFIC REPORTS, 2018, 8
[7]   AN IMPROVED 3-COIL SYSTEM FOR PRODUCING A UNIFORM MAGNETIC FIELD [J].
BARKER, JR .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1950, 27 (07) :197-199
[8]  
Cherif A, 2016, P 7 INT PART ACC C I, DOI 10.18429/JACOW-IPAC2016-MOOCB01
[9]   Cylindrical magnets and ideal solenoids [J].
Derby, Norman ;
Olbert, Stanislaw .
AMERICAN JOURNAL OF PHYSICS, 2010, 78 (03) :229-235
[10]  
Herr W., 2006, CONCEPT LUMINOSITY