How does concrete strength affect the fire resistance?

被引:4
作者
Lubloy, Eva [1 ]
机构
[1] Budapesti Muszaki Gazdasagtudomanyi Egyet, Dept Construct Mat & Technol, Budapest, Hungary
关键词
Concrete; Fire resistance; Structural elements; TT panels; Wall elements; BEHAVIOR; HPC;
D O I
10.1108/JSFE-10-2019-0035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Purpose The aim of the research was to investigate the effect of concrete strength on the fire resistance of structures. At first, it may seem contradictory that higher concrete strengths can decrease the fire resistance of building structures. However, if the strength of the concrete exceeds a maximum value, the risk of spalling (the detachment of the concrete surface) significantly. Design/methodology/approach Prefabricated structural elements are often produced with higher strength. The higher concrete strengths generally do not cause a reduction in the load bearing capacity, but it can have serious consequences in case of structural fire design. Results of two prefabricated elements, namely, one slab (TT shaped panel) and one single layer wall panel, were examined. Results of the specimen with the originally designed composition and a specimen with modified concrete composition were examined, were polymer fibres were added to prevent spalling. Findings As a result of the experiments, more strict regulations in the standards the author is suggested including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is required after polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons. Originality/value As a result of the experiments, the author suggests including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is necessary to require the addition of polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons.
引用
收藏
页码:311 / 324
页数:14
相关论文
共 17 条
[1]  
[Anonymous], 2012, 13652 MSZ PR EN
[2]  
[Anonymous], 2020, CONCR 1
[3]  
[Anonymous], DTSCH AUSSCHUSSTAH
[4]   Fire Induced Spalling in High Strength Concrete Beams [J].
Dwaikat, M. B. ;
Kodur, V. K. R. .
FIRE TECHNOLOGY, 2010, 46 (01) :251-274
[5]   Limits of spalling of fire-exposed concrete [J].
Hertz, KD .
FIRE SAFETY JOURNAL, 2003, 38 (02) :103-116
[6]  
Hinrichsmeyer K., 1987, Strukturorientierte Analyse und Modellbeschreibung der thermischen Schadigung von Beton
[7]  
Hoj N. P., 2005, P FIB S KEEP CONCR A, P1097
[8]   Spalling and pore pressure in HPC at high temperatures [J].
Kalifa, P ;
Menneteau, FD ;
Quenard, D .
CEMENT AND CONCRETE RESEARCH, 2000, 30 (12) :1915-1927
[9]   High-temperature behaviour of HPC with polypropylene fibres -: From spalling to microstructure [J].
Kalifa, P ;
Chéné, G ;
Gallé, C .
CEMENT AND CONCRETE RESEARCH, 2001, 31 (10) :1487-1499
[10]   TRANSIENT THERMAL STRAIN OF CONCRETE - LITERATURE-REVIEW, CONDITIONS WITHIN SPECIMEN AND BEHAVIOR OF INDIVIDUAL CONSTITUENTS [J].
KHOURY, GA ;
GRAINGER, BN ;
SULLIVAN, PJE .
MAGAZINE OF CONCRETE RESEARCH, 1985, 37 (132) :131-144