Applying analytic hierarchy process to the evaluation of double skin facades

被引:11
作者
Bostancioglu, Esra [1 ]
Onder, N. Pinar [2 ,3 ]
机构
[1] Istanbul Kultur Univ, Architecture Dept, Istanbul, Turkey
[2] Istanbul Eyup Municipal, Istanbul, Turkey
[3] Onderhan Construct, Istanbul, Turkey
关键词
Double-skin facade (DSF); analytic hierarchy process (AHP); multi-storey DSF; corridor DSF; shaft box DSF; box window DSF; LIFE-CYCLE ASSESSMENT; PROCESS AHP; SELECTION; ENERGY; BUILDINGS; MODEL; PERSPECTIVES; PERFORMANCE; VENTILATION; TECHNOLOGY;
D O I
10.1080/17452007.2018.1515062
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A double skin facade (DSF) mediates the interaction between the outdoor environment and internal space, while also providing architectural flexibility to the building design. Designers and builders should evaluate DSF alternatives before selection of a design solution for a specific project context. In this study, Analytic Hierarchy Process (AHP) was used to evaluate questionnaire responses from experienced professionals. DSF alternatives and evaluation criteria were identified from the literature review and the hierarchical structure was determined based on the alternatives and the evaluation criteria. The evaluation criteria were used to measure and evaluate DSF. Experienced professionals evaluated criteria and DSF alternatives. The findings of this study provide designers and builders with valuable insights into DSF evaluation factors and DSF alternatives. The results may help designers and builders with the selection of facade systems.
引用
收藏
页码:66 / 82
页数:17
相关论文
共 58 条
[1]   Using analytic hierarchy process (AHP) to improve human performance: An application of multiple criteria decision making problem [J].
Albayrak, E ;
Erensal, YC .
JOURNAL OF INTELLIGENT MANUFACTURING, 2004, 15 (04) :491-503
[2]   Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade [J].
Andelkovic, Aleksandar S. ;
Gvozdenac-Urosevic, Branka ;
Kljajic, Miroslav ;
Ignjatovic, Marko G. .
ENERGY AND BUILDINGS, 2015, 86 :766-781
[3]  
Arditi D., 1997, Int. J. Project Manag., V15, P235, DOI DOI 10.1016/S0263-7863(96)00076-2
[4]   A combined AHP-GP model for quality control systems [J].
Badri, MA .
INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2001, 72 (01) :27-40
[5]   Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin facade in Mediterranean climates [J].
Ballestini, G ;
De Carli, M ;
Masiero, N ;
Tombola, G .
BUILDING AND ENVIRONMENT, 2005, 40 (07) :983-995
[6]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[7]   Example of a Hybrid Life-Cycle Assessment of Construction Processes [J].
Bilec, Melissa ;
Ries, Robert ;
Matthews, H. Scott ;
Sharrard, Aurora L. .
JOURNAL OF INFRASTRUCTURE SYSTEMS, 2006, 12 (04) :207-215
[8]  
Bottani E., 2005, INT J LOGISTICS, V8, P249
[9]  
Boucher TO., 1991, ENG ECON, V37, P1, DOI DOI 10.1080/00137919108903055
[10]   An approach for the evaluation of energy and cost efficiency of glass facades [J].
Cetiner, I ;
Özkan, E .
ENERGY AND BUILDINGS, 2005, 37 (06) :673-684