Power quality and transient analysis for a utility-tied interfaced distributed hybrid wind-hydro controls renewable energy generation system using generic and multiband power system stabilizers

被引:14
作者
Sharma, Kamal Kant [1 ]
Gupta, Akhil [2 ]
Kaur, Gagandeep [3 ]
Kumar, Raman [4 ]
Chohan, Jasgurpreet Singh [4 ]
Sharma, Shubham [5 ]
Singh, Jujhar [5 ]
Khalilpoor, Nima [6 ]
Issakhov, Alibek [7 ]
机构
[1] Chandigarh Univ, Dept Elect Engn, Mohali 140413, Punjab, India
[2] IK Gujral Punjab Tech Univ, Elect Engn Dept, Main Campus, Kapurthala 144603, Punjab, India
[3] IK Gujral Punjab Tech Univ, Dept Elect Engn, Main Campus, Kapurthala 144603, Punjab, India
[4] Chandigarh Univ, Dept Mech Engn, Mohali 140413, Punjab, India
[5] IK Gujral Punjab Tech Univ, Dept Mech Engn, Main Campus, Kapurthala 144603, India
[6] Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
[7] Al Farabi Kazakh Natl Univ, Fac Mech & Math, Dept Math & Comp Modelling, Alma Ata, Kazakhstan
关键词
Utility-grid; Distributed energy; Power system stabilizer; Wind; Power quality; Hydro; COORDINATION; PROTECTION; DESIGN;
D O I
10.1016/j.egyr.2021.08.031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to its inherent ability of augmenting power system stability limit while maintaining good electric Power Quality (PQ), Power System Stabilizer (PSS) is envisaged to be an effective device in numerous Distributed Generation (DG) applications. It becomes a paramount work to maintain stable frequency, and alleviate the utility-grid collapse. Owing to this, this paper evaluates the performance of generic, and Multiband (MB)-PSSs for a hybrid 9 MW wind farm connected with mini/micro hydro power plant. The proposed system is interfaced with 200 MVA, 25 kV utility-grid system. A comparative analysis in the performance of a generic-PSS is presented with a MB-PSS at various voltage level points and power flows at various Point of Common Couplings (PCC) are analysed. Transient analysis is carried out during the presence of various unsymmetrical faults. It is envisaged that transients and unbalanced voltage sag-swells are mitigated at various PCCs while maintaining uninterruptable real and reactive power flows. The superiority of MB-PSS is established over generic-PSS in maintaining optimal PQ flow. Consequently, the reactive power requirement of the connected load is compensated by wind and mini/micro hydro controlling schemes using MB-PSS. Overall, the accurateness of the developed simulink models is demonstrated and satisfactory results are obtained in comparative analysis of both stabilizers. (C) 2021 Published by Elsevier Ltd.
引用
收藏
页码:5034 / 5044
页数:11
相关论文
共 22 条
[1]  
Abido MA, 2001, 2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, P1346, DOI 10.1109/PESS.2001.970272
[2]   A New Configuration of Vertically Connecting Solar Cells: Solar Tree [J].
Baci, Anouar Bella ;
Salmi, Mohamed ;
Menni, Younes ;
Ghafourian, Samira ;
Sadeghzadeh, Milad ;
Ghalandari, Mohammad .
INTERNATIONAL JOURNAL OF PHOTOENERGY, 2020, 2020 (2020)
[3]   Design of robust modified power system stabilizer for dynamic stability improvement using Particle Swarm Optimization technique [J].
Butti, Dasu ;
Mangipudi, Siva Kumar ;
Rayapudi, Srinivasa Rao .
AIN SHAMS ENGINEERING JOURNAL, 2019, 10 (04) :769-783
[4]   An on-line relay coordination algorithm for adaptive protection using linear programming technique [J].
Chattopadhyay, B ;
Sachdev, MS ;
Sidhu, TS .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :165-173
[5]   A decision support technique for the design of hybrid solar-wind power systems [J].
Chedid, R ;
Akiki, H ;
Rahman, S .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1998, 13 (01) :76-83
[6]   Modeling distributed energy resource dynamics on the transmission system [J].
Guttromson, RT .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (04) :1148-1153
[7]   Dynamic modelling of wind farm grid interaction [J].
Hansen, Anca D. ;
Sørensen, Paul ;
Blaabjerg, Frede ;
Becho, John .
Wind Engineering, 2002, 26 (04) :191-210
[8]  
Hiskens I. A., 1998, ISCAS '98. Proceedings of the 1998 IEEE International Symposium on Circuits and Systems (Cat. No.98CH36187), P439, DOI 10.1109/ISCAS.1998.704044
[9]   Trajectory sensitivity analysis of hybrid systems [J].
Hiskens, IA ;
Pai, MA .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2000, 47 (02) :204-220
[10]  
Marnay C, 2001, 2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, P150, DOI 10.1109/PESW.2001.917022