Improved Detection of Subendocardial Hyperenhancement in Myocardial Infarction Using Dark Blood-Pool Delayed Enhancement MRI

被引:30
作者
Farrelly, Cormac [1 ]
Rehwald, Wolfgang [2 ]
Salerno, Michael [3 ]
Davarpanah, Amir [1 ]
Keeling, Aoife N. [1 ]
Jacobson, Jason T. [4 ]
Carr, James C. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Cardiovasc Imaging Sect, Chicago, IL 60611 USA
[2] Duke Univ, Med Ctr, Cardiovasc MR Ctr, Durham, NC USA
[3] Univ Virginia Hlth Syst, Dept Cardiovasc Med, Charlottesville, VA USA
[4] Northwestern Univ, Feinberg Sch Med, Bluhm Cardiovasc Inst, Chicago, IL 60611 USA
关键词
cardiac MRI; dark blood-pool delayed enhancement; delayed enhanced imaging; myocardial infarction; MICROVASCULAR OBSTRUCTION; TRANSMURAL EXTENT; CONTRAST; ECHOCARDIOGRAPHY; VISUALIZATION; REPERFUSION; VIABILITY; NOISE; HEART; MODEL;
D O I
10.2214/AJR.10.4418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Delayed enhancement MRI using fast segmented k-space inversion recovery (IR) gradient-echo imaging is a well established "bright-blood" technique for identifying myocardial infarction and is used as the reference standard sequence in this study. The purpose of this study was to validate a recently developed dark blood-pool delayed enhancement technique in a porcine animal model, evaluate its performance in human patients, and quantify its performance compared with the reference standard in both. SUBJECTS AND METHODS. In an animal study, the reference standard and dark blood-pool delayed enhancement were assessed in three pigs with induced myocardial infarction. In a human study, 26 patients, 31-81 years old (19 men and seven women), with a known history of myocardial infarction were imaged using the reference standard and dark blood-pool delayed enhancement. Contrast-to-noise ratio (CNR), signal intensity ratio, signal-to-noise ratio (SNR), and qualitative scores of hyperenhancement were recorded. Measurements were compared using paired samples t test and Wilcoxon's signed rank test. RESULTS. In the animal study, the mean CNR of infarct to blood pool was 11 times higher for dark blood-pool delayed enhancement than for the reference standard. The mean SNR was 4.4 times higher for the reference standard. In the human study, the mean CNR and signal intensity ratio of hyperenhancing myocardium to the blood pool were 1.9 (p = 0.04) and 5.5 (p < 0.01) times higher, respectively, for dark blood-pool delayed enhancement compared with reference standard. The mean CNR and signal intensity ratio of hyperenhancing myocardium to normal myocardium and SNR were 2.8 (p < 0.01), 1.3 (p = 0.07), and 2.8 (p < 0.01) higher, respectively, for the reference standard. Qualitative analysis identified seven extra segments with grade 1 scars using dark blood-pool delayed enhancement (p < 0.01). CONCLUSION. Dark blood-pool delayed enhancement is complementary to the reference standard. It can detect more subendocardial foci of hyperenhancement, thus potentially identifying more infarcts and changing patient management.
引用
收藏
页码:339 / 348
页数:10
相关论文
共 34 条
  • [21] REHWALD WG, 2007, P INT SOC MAGN RES M
  • [22] REHWALD WG, 2007, J CARDIOVASC MAGN R, V9, P101
  • [23] SALERNO M, 2007, P INT SOC MAGN RES M
  • [24] Fast, three-dimensional free-breathing MR imaging of myocardial infarction: A feasibility study
    Saranathan, M
    Rochitte, CE
    Foo, TKF
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1055 - 1060
  • [25] Selvanayagam JB, 2004, CIRCULATION, V110, pE36
  • [26] Role of cardiac magnetic resonance imaging in the assessment of myocardial viability
    Shan, K
    Constantine, G
    Sivananthan, M
    Flamm, SD
    [J]. CIRCULATION, 2004, 109 (11) : 1328 - 1334
  • [27] An improved MR imaging technique for the visualization of myocardial infarction
    Simonetti, OP
    Kim, RJ
    Fieno, DS
    Hillenbrand, HB
    Wu, E
    Bundy, JM
    Finn, JP
    Judd, RM
    [J]. RADIOLOGY, 2001, 218 (01) : 215 - 223
  • [28] Single-shot T1- and T2-weighted magnetic resonance imaging of the heart with black blood: Preliminary experience
    Stehling, MK
    Holzknecht, NG
    Laub, G
    Bohm, D
    vonSmekal, A
    Reiser, M
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1996, 4 (3-4): : 231 - 240
  • [29] OCCLUSIVE AND REPERFUSED MYOCARDIAL INFARCTS - EFFECT OF GD-DTPA ON ECG-GATED MR IMAGING
    TSCHOLAKOFF, D
    HIGGINS, CB
    SECHTEM, U
    MCNAMARA, MT
    [J]. RADIOLOGY, 1986, 160 (02) : 515 - 519
  • [30] Delayed enhancement MR imaging: Utility in myocardial assessment
    Vogel-Claussen, Jens
    Rochitte, Carlos E.
    Wu, Katherine C.
    Kamel, Ihab R.
    Foo, Thomas K.
    Lima, Joao A. C.
    Bluemke, David A.
    [J]. RADIOGRAPHICS, 2006, 26 (03) : 795 - U168