Ultra-sensitive "turn-on" detection method for Hg2+ based on mispairing biosensor and emulsion PCR

被引:14
|
作者
Zhu, Pengyu [1 ]
Tian, Wenying [2 ]
Cheng, Nan [1 ]
Huang, Kunlun [1 ,2 ]
Luo, Yunbo [1 ,2 ]
Xu, Wentao [1 ,2 ]
机构
[1] China Agr Univ, Beijing Adv Innovat Ctr Food Nutr & Human Hlth, Coll Food Sci & Nutr Engn, Beijing 100094, Peoples R China
[2] China Agr Univ, Beijing Lab Food Qual & Safety, Coll Food Sci & Nutr Engn, Beijing 100094, Peoples R China
关键词
Mispairing biosensor; Emulsion PCR; Absolute quantitation; Hg2+; ELECTROCHEMICAL SENSOR; GRAPHENE OXIDE; DNA BIOSENSOR; MERCURY IONS; AMPLIFICATION; DESIGN; EMISSION; SAMPLES;
D O I
10.1016/j.talanta.2016.04.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensor-based detection methods have inspired the idea that chemical or physical signals could be converted to nucleic acid signals to be quantitatively detected using a combination of appropriate detection tools. To achieve ultra-sensitive and absolute quantitative detection of mercury ion (Hg2+), we have combined a mispairing biosensor for Hg2+ and emulsion PCR. The parameters that might influence the biosensor step, such as the duration of isothermal amplification and the concentration of the sensor oligonucleotide, have been firstly optimized in our study to achieve the most efficient biosensor detection. The evaluation results of secondary structures between the biosensors with different number of T-Hg-T structures achieved by Circular Dichroism have indicated that the secondary hairpin structure would be varied according to the change of number of T-Hg-T structures, which could influence the quantitative detection results. Further optimization of number of T-Hg-T within the biosensor sequences showed that 5 T-Hg-T structures could generate the most efficient amplification. After the above optimizations, the emulsion PCR has been employed to achieve the absolute quantitation of nucleic acid signals. The final results have shown that the limit of quantitation (LOQ) in our study was as low as 40 fmol, and the limit of detection (LOD) was 10 fmol. The practical detection tests showed that the quantitative results were stable and accurate for all substrates. In conclusion, by combining a mispairing biosensor with emulsion PCR, we developed a flexible and stable quantitative "turn-on" detection method with ultra-sensitivity that can detect trace amounts Hg2+ within different substrates. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [1] Ultra-sensitive and selective Hg2+ detection based on fluorescent carbon dots
    Liu, Ruihua
    Li, Haitao
    Kong, Weiqian
    Liu, Juan
    Liu, Yang
    Tong, Cuiyan
    Zhang, Xing
    Kang, Zhenhui
    MATERIALS RESEARCH BULLETIN, 2013, 48 (07) : 2529 - 2534
  • [2] ExoIII and TdT dependent isothermal amplification (ETDA) colorimetric biosensor for ultra-sensitive detection of Hg2+
    Li, XiangYang
    Du, ZaiHui
    Lin, Shenghao
    Tian, JingJing
    Tian, HongTao
    Xu, WenTao
    FOOD CHEMISTRY, 2020, 316
  • [3] A "turn-on" fluorescent probe for ultra-sensitive detection of β-galactosidase
    Niu, Yan
    Wang, Haoping
    Wang, Yunxia
    Feng, Liheng
    MICROCHEMICAL JOURNAL, 2021, 166
  • [4] Graphene nanosensor for highly sensitive fluorescence turn-on detection of Hg2+ based on target recycling amplification
    Wei, Yulian
    Zhou, Wenjiao
    Xu, Yunying
    Xiang, Yun
    Yuan, Ruo
    Chai, Yaqin
    RSC ADVANCES, 2014, 4 (73): : 39082 - 39086
  • [5] Highly sensitive and selective fluorescence detection of Hg2+ based on turn-on aptamer DNA silver nanoclusters
    Zhang, Baozhu
    Wei, Chunying
    RSC ADVANCES, 2017, 7 (89) : 56289 - 56295
  • [6] Aptasensor based on cascaded fluorescent sensor assisted by exonuclease III for ultra-sensitive detection of Hg2+
    Liu, Xing
    Liu, Zhen
    Pan, Yiliang
    Xiao, Xilin
    Analytical Sciences, 2024,
  • [7] An ultra-sensitive and ratiometric fluorescent probe based on the DTBET process for Hg2+ detection and imaging applications
    Jiang, Yin
    Duan, Qinya
    Zheng, Guansheng
    Yang, Liu
    Zhang, Jie
    Wang, Yafeng
    Zhang, Huatang
    He, Jun
    Sun, Hongyan
    Ho, Derek
    ANALYST, 2019, 144 (04) : 1353 - 1360
  • [8] Aptasensor based on cascaded fluorescent sensor assisted by exonuclease III for ultra-sensitive detection of Hg2+
    Liu, Xing
    Liu, Zhen
    Pan, Yiliang
    Xiao, Xilin
    ANALYTICAL SCIENCES, 2025, 41 (01) : 63 - 69
  • [9] A colorimetric/fluorescent dual-mode sensor for ultra-sensitive detection of Hg2+
    Yu, Tao
    Zhang, Ting-Ting
    Zhao, Wei
    Xu, Jing-Juan
    Chen, Hong-Yuan
    TALANTA, 2017, 165 : 570 - 576
  • [10] A Schiff-based sensor with turn-on fluorescence for selective detection of Hg2+
    Wan, Chin-Feng
    Lin, Hsiang-Yi
    Chien, Cho
    Wu, An-Tai
    LUMINESCENCE, 2014, 29 (06) : 698 - 701