Rapid, arteriovenous graft failure due to intimal hyperplasia: A porcine, bilateral, carotid arteriovenous graft model

被引:66
作者
Rotmans, JI
Velema, E
Verhagen, HJM
Blankensteijn, JD
Kastelein, JJP
de Kleijn, DPV
Yo, M
Pasterkamp, G
Stroes, ESG
机构
[1] Acad Med Ctr, Dept Vasc Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Expt Cardiol, Utrecht, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Vasc Surg, Utrecht, Netherlands
关键词
AV-graft failure; animal model; pig; intimal hyperplasia; vascular access;
D O I
10.1016/S0022-4804(03)00228-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The loss of patency constitutes the major complication of arteriovenous (AV) polytetrafluoroethylene hemodialysis grafts. In most cases, this graft failure is due to intimal hyperplasia at the venous outflow tract, including proliferation of vascular, smooth muscle cells and fibroblasts with deposition of extracellular matrix proteins. Thus far, procedures developed for improving patency have proven unsuccessful, which can be partly explained by the lack of relevant animal models. For this purpose, we developed a porcine model for AV graft failure that will allow the assessment of promising therapeutic strategies in the near future. Materials and methods. In 14 pigs, AV grafts were created bilaterally between the carotid artery and the jugular vein using expanded polytetrafluoroethylene. Two, 4 or 8 weeks after AV shunting, the grafts and adjacent vessels were excised and underwent histologic analysis. Results. From 2 weeks onwards, a thick neo-intima developed at the venous anastomosis, predominantly consisting of a-actin-positive vascular smooth muscle cells (VSMC). Intimal area increased over time, coinciding with a decreased graft flow. Grafts remained patent for at least 4 weeks. At 8 weeks, patency rates declined to less than 50% due to thrombus formation superimposed on progressive neo-intima formation. Conclusions. Implantation of an AV graft between the carotid artery and jugular vein in pigs causes a rapid neo-intimal response, accompanied by a loss of patency of 50% at 8 weeks after surgery. This model offers a suitable tool to study local interventions aimed at the improvement of AV graft patency rates. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:161 / 171
页数:11
相关论文
共 61 条
[1]   ANASTOMOTIC INTIMAL HYPERPLASIA - MECHANICAL INJURY OR FLOW INDUCED [J].
BASSIOUNY, HS ;
WHITE, S ;
GLAGOV, S ;
CHOI, E ;
GIDDENS, DP ;
ZARINS, CK .
JOURNAL OF VASCULAR SURGERY, 1992, 15 (04) :708-717
[2]   The matrix metalloproteinase inhibitor BB-94 limits expansion of experimental abdominal aortic aneurysms [J].
Bigatel, DA ;
Elmore, JR ;
Carey, DJ ;
Cizmeci-Smith, G ;
Franklin, DP ;
Youkey, JR .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (01) :130-138
[3]   Haemodialysis access without thrombosis: Is it possible? [J].
Blankestijn, PJ ;
Bosman, PJ ;
Boereboom, FTJ .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (12) :2394-2397
[4]   Graft flow as a predictor of thrombosis in hemodialysis grafts [J].
Bosman, PJ ;
Boereboom, FTJ ;
Eikelboom, BC ;
Koomans, HA ;
Blankestijn, PJ .
KIDNEY INTERNATIONAL, 1998, 54 (05) :1726-1730
[5]   Tenascin: A potential role in human arteriovenous PTFE graft failure [J].
Chen, CY ;
Ku, DN ;
Kikeri, D ;
Lumsden, AB .
JOURNAL OF SURGICAL RESEARCH, 1996, 60 (02) :409-416
[6]   Atherosclerotic cardiovascular disease risks in chronic hemodialysis patients [J].
Cheung, AK ;
Sarnak, MJ ;
Yan, GF ;
Dwyer, JT ;
Heyka, RJ ;
Rocco, MV ;
Teehan, BP ;
Levey, AS .
KIDNEY INTERNATIONAL, 2000, 58 (01) :353-362
[7]   A DILEMMA FOR THE 1990S - CHOOSING APPROPRIATE EXPERIMENTAL ANIMAL-MODEL FOR THE PREVENTION OF RESTENOSIS [J].
FERRELL, M ;
FUSTER, V ;
GOLD, HK ;
CHESEBRO, JH .
CIRCULATION, 1992, 85 (04) :1630-1631
[8]   BENEFICIAL-EFFECTS OF BANDING ON VENOUS INTIMAL-MEDIAL HYPERPLASIA IN ARTERIOVENOUS LOOP GRAFTS [J].
FILLINGER, MF ;
REINITZ, ER ;
SCHWARTZ, RA ;
RESETARITS, DE ;
PASKANIK, AM ;
BREDENBERG, CE .
AMERICAN JOURNAL OF SURGERY, 1989, 158 (02) :87-94
[9]   GRAFT GEOMETRY AND VENOUS INTIMAL-MEDIAL HYPERPLASIA IN ARTERIOVENOUS LOOP GRAFTS [J].
FILLINGER, MF ;
REINITZ, ER ;
SCHWARTZ, RA ;
RESETARITS, DE ;
PASKANIK, AM ;
BRUCH, D ;
BREDENBERG, CE .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (04) :556-566
[10]   Intracoronary brachytherapy in the porcine model - A different animal [J].
Fischell, TA ;
Virmani, R .
CIRCULATION, 2001, 104 (20) :2388-2390