Qualitative and quantitative characterization of the In Vitro dehydration process of hydrogel contact lenses

被引:29
作者
Gonzalez-Meijome, Jose M. [1 ]
Lopez-Alemany, Antonio
Almeida, Jose B.
Parafita, Manuel A.
Refojo, Miguel F.
机构
[1] Univ Minho, Dept Phys Optometry, Sch Sci, Braga, Portugal
[2] Univ Valencia, Ocular Surface Cornea & Contact Lens Res Grp, Dept Opt, Sch Optometry & Opt, E-46003 Valencia, Spain
[3] IOOC, Novetle, Spain
[4] Univ Santiago de Compostela, Dept Surg Ophthalmol, Sch Opt & Optometry, Santiago De Compostela, Spain
[5] Harvard Univ, Sch Med, Schepens Eye Res Inst, Boston, MA USA
关键词
gravimetry; hydration; hydrogel; silicone-hydrogel; contact lenses; dehydration;
D O I
10.1002/jbm.b.30824
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To investigate the in vitro dehydration process of conventional hydrogell and sillicone-hydrogell contact lens materials. Methods: Eight conventional hydrogell and five silicone-hydrogel contact lenses were dehydrated under controlled environmental conditions on an analytical balance. Data were taken at 1-min intervals and dehydration curves of cumulative dehydration (CD), valid dehydration (VD), and dehydration rate (DR) were obtained. Several quantitative descriptors of the dehydration process were obtained by further processing of the information. Results: Duration of phase I (r(2) = 0.921), CD at end of phase I (r(2) = 0.971), time to achieve a DR of -1%/min (r(2) = 0.946) were strongly correlated with equilibrium water content (EWC) of the materials. For each individual sample, the VD at different time intervals can be accurately determined using a 2nd order regression equation (r(2) > 0.99 for all samples). The first 5 min of the dehydration process show a relatively uniform average CD of about - 1.5%/min. After that, there was a trend towards higher average CD for the following 15 min as the EWC of the material increases (r(2) = 0.701). As a consequence, average VD for the first 5 min displayed a negative correlation with EWC (r(2) = 0.835), and a trend towards uniformization among CL materials for the following periods (r(2) = 0.014). Overall, sillicone-hydrogell materials display a lower dehydration, but this seems to be primarily due to their lower EWC. Conclusions: DR curves under the conditions of the present study can be described as a three-phase process. Phase I consists of a relatively uniform DR with a duration that ranges from 10 to almost 60 min and is strongly correlated with the EWC of the polymer as it is the CD during this phase. Overall, HEMA-based hydrogels dehydrate to a greater extent and faster than silicone-hydrogel materials. There are differences in water retention between lenses of similar water content and thickness that should be further investigated. (C) 2007 Wiley Periodicals. Inc.
引用
收藏
页码:512 / 526
页数:15
相关论文
共 36 条
[11]   Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses [J].
González-Méijome, JM ;
Lira, M ;
López-Alemany, A ;
Almeida, JB ;
Parafita, MA ;
Refojo, MF .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (01) :57-64
[12]   Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manual refractometry [J].
Gonzalez-Meijome, Jose M. ;
Lopez-Alemany, Antonio ;
Lira, Madalena ;
Almeida, Jose B. ;
Oliveira, M. Elisabete C. D. Real ;
Parafita, Manuel A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 80B (01) :184-191
[13]  
GONZALEZMEIJOME JM, 2007, IN PRESS OPTOM VIS, V84, P4
[14]  
Jones L, 2002, Cont Lens Anterior Eye, V25, P147, DOI 10.1016/S1367-0484(02)00033-4
[15]  
Jones Lyndon, 1997, CLAO Journal, V23, P122
[16]  
Lemp Michael A., 1999, CLAO Journal, V25, P40
[17]  
Lloyd A W, 2000, Cont Lens Anterior Eye, V23, P119, DOI 10.1016/S1367-0484(00)80004-1
[18]   Porous structure of Purevision™ versus Focus® night&day™ and conventional hydrogel contact lenses [J].
López-Alemany, A ;
Compan, V ;
Refojo, MF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (03) :319-325
[19]  
Maldonado-Codina Carole, 2005, Eye Contact Lens, V31, P270, DOI 10.1097/01.ICL.0000163432.74952.1A
[20]   Effect of environmental conditions on tear dynamics in soft contact lens wearers [J].
Maruyama, K ;
Yokoi, N ;
Takamata, A ;
Kinoshita, S .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) :2563-2568