Agreement between Heidelberg Retina Tomograph-I and -II in detecting glaucomatous changes using topographic change analysis

被引:4
作者
Balasubramanian, M. [1 ]
Bowd, C. [1 ]
Weinreb, R. N. [1 ]
Zangwill, L. M. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
glaucoma; progression; optic disk topography; topographic change analysis; agreement; parabolic error correction; SCANNING LASER TOMOGRAPHY; OPTIC DISC; VISUAL-FIELD; PROGRESSION; IMAGES;
D O I
10.1038/eye.2010.124
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the suitability of including both Heidelberg Retina Tomograph-I (HRT-I) and HRT-II examinations in the same longitudinal series for HRT topographic change analysis (TCA) and to evaluate parabolic error correction (PEC) to improve the agreement between HRT-I and HRT-II examinations. Methods A total of 66 eyes from the University of California San Diego Diagnostic Innovations in Glaucoma Study with baseline HRT-I and HRT-II examinations obtained on the same day and >= 3 HRT-II follow-up examinations were included. Two TCA analyses, HRT-I examination at baseline (HRT-I-mixed series) and HRT-II examination at baseline (HRT-II-only series) were compared. Agreement between the HRT-I-mixed and HRT-II-only series were estimated using Bland-Altman plots. Agreement was assessed: (1) using the current HRT software settings (PEC applied only to HRT-II-only series), and (2) modified HRT settings (PEC also applied to HRT-I-mixed series). Results With current HRT software settings, the HRT-I-mixed series significantly overestimated change locations (ie, red pixels) compared with the HRT-II-only series as indicated by statistically significant proportional biases in the Bland-Altman analysis. By applying PEC to HRT-I-mixed series there were no statistically significant biases in the TCA parameter estimates compared with the HRT-II-only series. Conclusion In some eyes, HRT-I and HRT-II baseline examinations are not interchangeable in TCA analysis without parabolic error correction. HRT-I-mixed series detected more changes characteristic of glaucoma when there were only minimal changes in the HRT-II-only series. Our results suggest that in the majority of cases, with PEC, HRT-I examinations may be included in a longitudinal series containing HRT-II examinations. Eye (2011) 25, 31-42; doi: 10.1038/eye.2010.124; published online 1 October 2010
引用
收藏
页码:31 / 42
页数:12
相关论文
共 17 条
  • [1] Longitudinal changes in the visual field and optic disc in glaucoma
    Artes, PH
    Chauhan, BC
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2005, 24 (03) : 333 - 354
  • [2] BALASUBRAMANIAN M, 2011, OPTOM VIS S IN PRESS, V88
  • [3] A Framework for Detecting Glaucomatous Progression in the Optic Nerve Head of an Eye Using Proper Orthogonal Decomposition
    Balasubramanian, Madhusudhanan
    Zabic, Stanislav
    Bowd, Christopher
    Thompson, Hilary W.
    Wolenski, Peter
    Iyengar, S. Sitharama
    Karki, Bijaya B.
    Zangwill, Linda M.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (05): : 781 - 793
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Performance of Confocal Scanning Laser Tomograph Topographic Change Analysis (TCA) for Assessing Glaucomatous Progression
    Bowd, Christopher
    Balasubramanian, Madhusudhanan
    Weinreb, Robert N.
    Vizzeri, Gianmarco
    Alencar, Luciana M.
    O'Leary, Neil
    Sample, Pamela A.
    Zangwill, Linda M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) : 691 - 701
  • [7] Optic Disc Progression in Glaucoma: Comparison of Confocal Scanning Laser Tomography to Optic Disc Photographs in a Prospective Study
    Chauhan, Balwantray C.
    Hutchison, Donna M.
    Artes, Paul H.
    Caprioli, Joseph
    Jonas, Jost B.
    LeBlanc, Raymond P.
    Nicolela, Marcelo T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (04) : 1682 - 1691
  • [8] Chauhan BC, 2001, ARCH OPHTHALMOL-CHIC, V119, P1492
  • [9] Chauhan BC, 2000, INVEST OPHTH VIS SCI, V41, P775
  • [10] Off-axis aberrations of a wide-angle schematic eye model
    Escudero-Sanz, I