Differential absorption imaging with optical coherence tomography

被引:118
作者
Schmitt, JM [1 ]
Xiang, SH [1 ]
Yung, KM [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
D O I
10.1364/JOSAA.15.002288
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The spatial variation of the backscattering cross section is the primary source of contrast in present applications of optical coherence tomography (OCT). We introduce and analyze a technique for obtaining OCT images of the local concentration of an absorbing compound in biological tissues and other highly scattering media. A pair of light-emitting diodes, one emitting in a vibrational absorption band of the chemical compound of interest and the other emitting just outside this band, are used as sources at the input of the interferometer. The differential absorption of the probe beam is determined by Fourier transformation and ratiometric processing of the measured interference signals. The ability of the technique to distinguish lipid and water inclusions in a scattering material is demonstrated with an OCT system that uses a pair of light-emitting-diode sources with center wavelengths of 1.3 mu m and 1.46 mu m. (C) 1998 Optical Society of America.
引用
收藏
页码:2288 / 2296
页数:9
相关论文
共 18 条
  • [1] INVERSE SCATTERING FOR DISCRETE TRANSMISSION-LINE MODELS
    BRUCKSTEIN, AM
    KAILATH, T
    [J]. SIAM REVIEW, 1987, 29 (03) : 359 - 389
  • [2] Cheng XD, 1997, ACUPUNCTURE ELECTRO, V22, P1
  • [3] Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    deBoer, JF
    Milner, TE
    vanGemert, MJC
    Nelson, JS
    [J]. OPTICS LETTERS, 1997, 22 (12) : 934 - 936
  • [4] Birefringence characterization of biological tissue by use of optical coherence tomography
    Everett, MJ
    Schoenenberger, K
    Colston, BW
    Da Silva, LB
    [J]. OPTICS LETTERS, 1998, 23 (03) : 228 - 230
  • [5] Linear propagation of light investigated with a white-light Michelson interferometer
    Fuji, T
    Miyata, M
    Kawato, S
    Hattori, T
    Nakatsuka, H
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1997, 14 (05) : 1074 - 1078
  • [6] POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING
    HEE, MR
    HUANG, D
    SWANSON, EA
    FUJIMOTO, JG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) : 903 - 908
  • [7] HITZENBERGER CK, 1992, INVEST OPHTH VIS SCI, V33, P98
  • [8] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [9] Optical coherence tomography and microscopy in gastrointestinal tissues
    Izatt, JA
    Kulkarni, MD
    Wang, HW
    Kobayashi, K
    Sivak, MV
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) : 1017 - 1028
  • [10] MULTIWAVELENGTH LIDAR FOR OZONE MEASUREMENTS IN THE TROPOSPHERE AND THE LOWER STRATOSPHERE
    PAPAYANNIS, A
    ANCELLET, G
    PELON, J
    MEGIE, G
    [J]. APPLIED OPTICS, 1990, 29 (04): : 467 - 476