Cerclage wiring in displaced both-column fractures of the acetabulum

被引:35
作者
Chen, CM [1 ]
Chiu, FY [1 ]
Lo, WH [1 ]
Chung, TY [1 ]
机构
[1] Vet Gen Hosp, Dept Orthoped & Traumatol, Taipei 11217, Taiwan
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2001年 / 32卷 / 05期
关键词
D O I
10.1016/S0020-1383(00)00243-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We evaluated the effect of cerclage wiring in the open reduction and internal fixation of displaced both-column fractures of the acetabulum. This was a prospective clinical evaluation of such cases where the main surgical strategy was open reduction and internal fixation with cerclage wire and supplemental reconstruction plates. Data on 35 cases treated by open reduction tall via the triradiate approach)/internal fixations with cerclage wire and reconstruction plates were collected. The follow-up period was 40 months (18-69). Reduction with a fracture gap of less than 2 mm without articular stepping was achieved in all 35 cases. Postoperative complications developed in seven cases, including subcutaneous haematoma in two, wound infection in two and heterotopic ossification in three. All the complications had no adverse effect on the clinical outcome, and all the cases had good to excellent final results. Cerclage wiring is very useful and effective in the reduction and fixation of displaced both-column fractures of the acetabulum, and supplemental fixation with reconstruction plates and screws is necessary. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:391 / 394
页数:4
相关论文
共 12 条
[1]   SSEP MONITORING DURING PELVIC AND ACETABULAR FRACTURE SURGERY [J].
BAUMGAERTNER, MR ;
WEGNER, D ;
BOOKE, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (02) :127-133
[2]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]  
CALDER HB, 1994, CLIN ORTHOP RELAT R, P160
[4]  
GHALAMBOR N, 1994, CLIN ORTHOP RELAT R, P96
[5]  
Helfet D L, 1991, J Orthop Trauma, V5, P161, DOI 10.1097/00005131-199105020-00007
[6]  
Letournel E, 1993, FRACTURES ACETABULUM, P521
[7]  
MATTA JM, 1994, CLIN ORTHOP RELAT R, P10
[8]  
MAYO KA, 1994, CLIN ORTHOP RELAT R, P31
[9]   LOW-DOSE IRRADIATION AND INDOMETHACIN PREVENT HETEROTOPIC OSSIFICATION AFTER ACETABULAR FRACTURE SURGERY [J].
MOED, BR ;
LETOURNEL, E .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06) :895-900
[10]  
RUESCH PD, 1994, CLIN ORTHOP RELAT R, P38