Control of heat transfer in single-story mechanically ventilated double skin facades

被引:8
|
作者
Jankovic, Aleksandar [1 ]
Goia, Francesco [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Architecture & Technol, NTNU, Trondheim, Norway
关键词
Double-skin facade; Mechanical ventilation; Climate simulator; Design of experiment; Air preheating; Heat transfer; Convective heat gain; AIR-FLOW; PERFORMANCE; SIMULATION; BEHAVIOR;
D O I
10.1016/j.enbuild.2022.112304
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper systematically investigates and quantifies the interplay between mechanical ventilation rate and operation of venetian blinds in determining the performance of a single-story double skin facade. The investigation covers both the supply-air mode and the outdoor air curtain mode of a mechanically ventilated double skin facade. For this experimental study, a full-scale mock-up of a single-story double skin facade was installed in a climate simulator facility and exposed to a series of steady-state regime conditions under two representative cases of temperature gradient and solar irradiance replicating the summer, and the mid-season/winter case. The study results showed the relative weights of the different variables in leading the behavior of the facade. They provided evidence that the control of the performance of a double skin facade may change with the seasons, and that airflow rates and venetian blinds can play different roles depending on the boundary conditions and target performance. Venetian blinds were far more dominant than the mechanical ventilation rate in controlling the net heat transfer in the tested summer conditions, while the opposite was seen for the dynamic insulation efficiency. In midseason/winter conditions, while operating the facade in a supply-air operation mode, the mechanical ventilation rate was the dominant variable in controlling the net heat transfer. Recommendations for the operation of the double skin facade were also developed as a result of this study. Low and moderate ventilation rates (up to 100 m(3)h(-1) per linear meter of facade) were found suitable to deliver enough fresh air with good preheating efficiency while provide adequate control over the net heat transfer. Higher airflow rates, even in summer peak conditions, were not found to be particularly effective in reducing the solar gain through a facade operated in an outdoor air curtain mode when the interior skin was realized with an insulated glazed unit. (C) 2022 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Mechanically ventilated double skin facades
    Kragh, M
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1233 - 1240
  • [2] Modelling double skin facades (DSFs) in whole-building energy simulation tools: Validation and inter-software comparison of a mechanically ventilated single-story DSF
    Lucchino, Elena Catto
    Gelesz, Adrienn
    Skeie, Kristian
    Gennaro, Giovanni
    Reith, Andras
    Serra, Valentina
    Goia, Francesco
    BUILDING AND ENVIRONMENT, 2021, 199
  • [3] Airflow and heat transfer in double skin facades
    Jiru, Teshome Edae
    Tao, Yong-X.
    Haghighat, Fariborz
    ENERGY AND BUILDINGS, 2011, 43 (10) : 2760 - 2766
  • [4] Numerical analysis of the most appropriate heat transfer correlations for free ventilated double skin photovoltaic facades
    Cipriano, Jordi
    Houzeaux, Guillaume
    Chemisana, Daniel
    Lodi, Chiara
    Marti-Herrero, Jaime
    APPLIED THERMAL ENGINEERING, 2013, 57 (1-2) : 57 - 68
  • [5] Reliability and Sensitivity of Building Performance Simulation Tools in Simulating Mechanically Ventilated Double Skin Facades
    Gelesz, Adrienn
    Lucchino, Elena Catto
    Goia, Francesco
    Reith, Andras
    Serra, Valentina
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4490 - 4497
  • [6] Modelling double skin façades (DSFs) in whole-building energy simulation tools: Validation and inter-software comparison of a mechanically ventilated single-story DSF
    Catto Lucchino, Elena
    Gelesz, Adrienn
    Skeie, Kristian
    Gennaro, Giovanni
    Reith, András
    Serra, Valentina
    Goia, Francesco
    Building and Environment, 2021, 199
  • [7] Airflow patterns and thermal behavior of mechanically ventilated glass double facades
    Manz, H
    Schaelin, A
    Simmler, H
    BUILDING AND ENVIRONMENT, 2004, 39 (09) : 1023 - 1033
  • [8] Heat transfer and mass flow correlations for ventilated facades
    Suarez, Christian
    Joubert, Patrice
    Molina, Jose L.
    Sanchez, Francisco J.
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3696 - 3703
  • [9] Assessment of sound insulation of naturally ventilated double skin facades
    Urban, D.
    Roozen, N. B.
    Zat'ko, P.
    Rychtarikova, M.
    Tomasovic, P.
    Glorieux, C.
    BUILDING AND ENVIRONMENT, 2016, 110 : 148 - 160
  • [10] Measuring and estimating airflow in naturally ventilated double skin facades
    Marques da Silva, F.
    Gloria Gomes, M.
    Moret Rodrigues, A.
    BUILDING AND ENVIRONMENT, 2015, 87 : 292 - 301