Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system

被引:114
作者
Wilson, AJ [1 ]
Milnes, P [1 ]
Waterworth, AR [1 ]
Smallwood, RH [1 ]
Brown, BH [1 ]
机构
[1] Royal Hallamshire Hosp, Dept Med Phys & Clin Engn, Sheffield S10 2JF, S Yorkshire, England
关键词
impedance spectroscopy; instrumentation; modular;
D O I
10.1088/0967-3334/22/1/307
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes the Sheffield Mk3.5 EIT/EIS system which measures both the real and imaginary part of impedance at 30 frequencies between 2 kHz and 1.6 MHz. The system uses eight electrodes with an adjacent drive/receive electrode data acquisition protocol. The system is modular, containing eight identical data acquisition boards, which contain DSPs to generate the drive frequencies and to pel form the FFT used for demodulation. The current drive is in three sequentially applied packets, where each packet contains ten summed sine waves. The data acquisition system is interfaced to a host PC through an optically isolated high speed serial link (RS485) running at 2 Mbaud (2 Mbits s(-1)). Measurements on a saline filled tank show that the average signal to noise performance of the system is 40 dB measured across all frequencies and that this figure is independent of frequency of measurement. These results suggest that the current system is 10 dB better in absolute terms than the previous Sheffield (Mk3a) system.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 8 条
[1]   A comparison of modified Howland circuits as current generators with current mirror type circuits [J].
Bertemes, P ;
Brown, BH ;
Wilson, AJ .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :1-6
[2]  
Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
[3]   COMPUTER-CONTROLLED SELECTION OF SMALL INDUSTRIAL COMPONENTS USING LASER SCATTER [J].
BROWN, SM ;
DEWHURST, RJ .
OPTICS AND LASERS IN ENGINEERING, 1991, 15 (01) :1-15
[4]  
LU L, 1994, INNOV TECH BIOL MED, V15, P98
[5]  
LU L, 1995, THESIS U SHEFFIELD
[6]   Monitoring patients with left ventricular failure by electrical impedance tomography [J].
Noble, TJ ;
Morice, AH ;
Channer, KS ;
Milnes, P ;
Harris, ND ;
Brown, BH .
EUROPEAN JOURNAL OF HEART FAILURE, 1999, 1 (04) :379-384
[7]   Model for the dielectric properties of human lung tissue against frequency and air content [J].
Nopp, P ;
Harris, ND ;
Zhao, TX ;
Brown, BH .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (06) :695-702
[8]   A comparison of neonatal and adult lung impedances derived from EIT images [J].
Smallwood, RH ;
Hampshire, AR ;
Brown, BH ;
Primhak, RA ;
Marven, S ;
Nopp, P .
PHYSIOLOGICAL MEASUREMENT, 1999, 20 (04) :401-413