Complications Associated with the Percutaneous Insertion of Fiducial Markers in the Thorax

被引:103
作者
Bhagat, Nikhil [1 ]
Fidelman, Nicholas [1 ]
Durack, Jeremy C. [1 ]
Collins, Jeremy [1 ]
Gordon, Roy L. [1 ]
LaBerge, Jeanne M. [1 ]
Kerlan, Robert K., Jr. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
Fiducial marker; Complications; Pneumothorax; Migration; Lung neoplasm; RADIATION-THERAPY; REAL-TIME; BIOPSY;
D O I
10.1007/s00270-010-9949-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Radiosurgery requires precise lesion localization Fiducial markers enable lesion tracking, but complications from insertion may occur The purpose of this study was to describe complications of fiducial marker insertion into pulmonary lesions Materials and Methods Clinical and imaging records of 28 consecutive patients with 32 lung nodules or masses who underwent insertion of a total of 59 fiducial markers before radiosurgery were retrospectively reviewed Results Eighteen patients (67%) developed a pneumothorax and six patients (22%) required a chest tube The rates of pneumothorax were 82% and 40%, respectively when 18-gauge and 19-gauge needles were used for marker insertion (P = 0 01) Increased rate of pneumothorax was also associated with targeting smaller lesions (P = 0 03) and tumors not in contact with the pleural surface (P = 0 04) A total of 11 fiducials (19%) migrated after insertion into the pleural space (10 markers) or into the airway (1 marker) Migration was associated with shorter distances from pleura to the marker deposition site (P = 0 04) and with fiducial placement outside of the target lesion (P = 0 03) Conclusion Fiducial marker placement into lung lesions is associated with a high risk of pneumothorax and a risk individual migration.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 11 条
[1]  
COLLINS J, 2007, ANN M CARD INT RAD S
[2]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[3]   Safety and Efficacy of Percutaneous Fiducial Marker Implantation for Image-guided Radiation Therapy [J].
Kothary, Nishita ;
Heit, Jeremy J. ;
Louie, John D. ;
Kuo, William T. ;
Loo, Billy W., Jr. ;
Koong, Albert ;
Chang, Daniel T. ;
Hovsepian, David ;
Sze, Daniel Y. ;
Hofmann, Lawrence V. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (02) :235-239
[4]   Society of Interventional Radiology quality improvement guidelines for percutaneous vertebroplasty [J].
McGraw, K ;
Cardella, J ;
Barr, JD ;
Mathis, JM ;
Sanchez, O ;
Schwartzberg, MS ;
Swan, TL ;
Sacks, D .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (07) :827-831
[5]   Tracking moving organs in real time [J].
Murphy, MJ .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :91-100
[6]   Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy [J].
Shirato, H ;
Harad, T ;
Harabayashi, T ;
Hida, K ;
Endo, H ;
Kitamura, K ;
Onimaru, R ;
Yamazaki, K ;
Kurauchi, N ;
Shimizu, T ;
Shinohara, N ;
Matsushita, M ;
Dosaka-Akita, H ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :240-247
[7]   Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy [J].
Shirato, Hiroki ;
Shimizu, Shinichi ;
Kitamura, Kei ;
Onimaru, Rikiya .
INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (01) :8-16
[8]  
Uematsu M, 1998, CANCER-AM CANCER SOC, V82, P1062, DOI 10.1002/(SICI)1097-0142(19980315)82:6<1062::AID-CNCR8>3.0.CO
[9]  
2-G
[10]   PERCUTANEOUS TRANS-THORACIC NEEDLE-BIOPSY [J].
WESTCOTT, JL .
RADIOLOGY, 1988, 169 (03) :593-601