Hydrogen leak detection using laser-induced breakdown Spectroscopy

被引:40
作者
Ball, AJ [1 ]
Hohreiter, V [1 ]
Hahn, DW [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
关键词
laser-induced breakdown spectroscopy; LIBS; hydrogen; plasma; atomic emission;
D O I
10.1366/0003702053585282
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) is investigated as a technique for real-time monitoring of hydrogen gas. Two methodologies were examined: The use of a 100 mJ laser pulse to create a laser-induced breakdown directly in a sample gas stream, and the use of a 55 mJ laser pulse to create a laser-induced plasma on a solid substrate surface, with the expanding plasma sampling the gas stream. Various metals were analyzed as candidate substrate surfaces, including aluminum, copper, molybdenum, stainless steel, titanium, and tungsten. Stainless steel was selected, and a detailed analysis of hydrogen detection in binary mixtures of nitrogen and hydrogen at atmospheric pressure was performed. Both the gaseous plasma and the plasma initiated on the stainless steel surface generated comparable hydrogen emission signals, using the 656.28 H-alpha emission line, and exhibited excellent signal linearity. The limit of detection is about 20 ppm (mass) as determined for both methodologies, with the solid-initiated plasma yielding a slightly better value. Overall, LIBS is concluded to be a viable candidate for hydrogen sensing, offering a combination of high sensitivity with a technique that is well suited to implementation in field environments.
引用
收藏
页码:348 / 353
页数:6
相关论文
共 16 条
[1]   Curves of growth of spectral lines emitted by a laser-induced plasma:: influence of the temporal evolution and spatial inhomogeneity of the plasma [J].
Aguilera, JA ;
Bengoechea, J ;
Aragón, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (2-3) :221-237
[2]   Sampling statistics and considerations for single-shot analysis using laser-induced breakdown spectroscopy [J].
Carranza, JE ;
Hahn, DW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (04) :779-790
[3]   Time-resolved laser-induced breakdown spectroscopy: Application for qualitative and quantitative detection of fluorine, chlorine, sulfur, and carbon in air [J].
Dudragne, L ;
Adam, P ;
Amouroux, J .
APPLIED SPECTROSCOPY, 1998, 52 (10) :1321-1327
[4]   Laser-induced breakdown spectroscopy for on-line engine equivalence ratio measurements [J].
Ferioli, F ;
Puzinauskas, PV ;
Buckley, SG .
APPLIED SPECTROSCOPY, 2003, 57 (09) :1183-1189
[5]   New plasma diagnosis tables of hydrogen Stark broadening including ion dynamics [J].
Gigosos, MA ;
Cardenoso, V .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1996, 29 (20) :4795-4838
[6]  
Griem H. R., 1974, Spectral line broadening by plasmas
[7]   A fully-redundant, on-line, mass-spectrometer system used to monitor cryogenic fuel leaks on the Space Shuttle [J].
Griffin, TP ;
Breznik, GS ;
Mizell, CA ;
Helms, WR ;
Naylor, GR ;
Haskell, WD .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (08) :488-497
[8]   Temporal analysis of laser-induced plasma properties as related to laser-induced breakdown spectroscopy [J].
Hohreiter, V ;
Carranza, JE ;
Hahn, DW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (03) :327-333
[9]   Spatially resolved elemental analysis of a hydrogen-air diffusion flame by laser-induced plasma spectroscopy (LIPS) [J].
Itoh, S ;
Shinoda, M ;
Kitagawa, K ;
Arai, N ;
Lee, YI ;
Zhao, DQ ;
Yamashita, H .
MICROCHEMICAL JOURNAL, 2001, 70 (02) :143-152