Experimental and numerical study on the mechanical behaviour of CLT shearwalls with openings

被引:17
作者
Casagrande, Daniele [1 ]
Fanti, Riccardo [1 ]
Doudak, Ghasan [2 ]
Polastri, Andrea [1 ]
机构
[1] Natl Res Council Italy, Inst Bioecon, Via Francesco Biasi 75, I-38098 San Michele All Adige, Trento, Italy
[2] Univ Ottawa, Fac Civil Engn, 161 Louis Pasteur Piece, Ottawa, ON K1N 6N5, Canada
关键词
Shearwalls; Openings; Timber structures; Numerical models; Beam tests; Cross laminated timber; SEISMIC BEHAVIOR;
D O I
10.1016/j.conbuildmat.2021.123858
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An investigation of the mechanical behaviour of CLT shearwalls, where either door or window openings are cut out of the panel, is undertaken. The main aim of the study is to investigate failure modes related to either mechanical anchor or CLT panel, based on the geometrical dimensions and mechanical properties of shearwall. The results of six full-scale monolithic CLT shearwalls with window or door openings are presented and discussed. The results obtained from the full-scale shearwall tests are used to validate a proposed numerical model, where input parameters, such as the mechanical properties of the CLT panels and mechanical anchors, are obtained from component level tests on beams and connections in isolation. The study shows that differently from single-panel shearwalls with no openings, brittle failure in the CLT panels is a possible mode of failure, which needs to be considered in design. The failure mode in the CLT panels is observed to occur either in bending or net shear in the lintel beams. The proposed numerical procedure is found capable of estimating the maximum load with reasonable accuracy, and the model predictions of the failure mode, number of centre of rotations, and the overall deformation of the CLT panel are accurate for all the studied specimens. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 33 条
[1]   Analytical and Experimental Lateral-Load Response of Self-Centering Posttensioned CLT Walls [J].
Akbas, Tugce ;
Sause, Richard ;
Ricles, James M. ;
Ganey, Ryan ;
Berman, Jeffrey ;
Loftus, Sarah ;
Dolan, J. Daniel ;
Pei, Shiling ;
van de Lindt, John W. ;
Blomgren, Hans-Erik .
JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
[2]  
[Anonymous], 2020, 120362 ETA EUR EXP S
[3]  
[Anonymous], 2011, 594 EN
[4]  
[Anonymous], 2012, TIMB STRUCT STRUCT T
[5]  
[Anonymous], 2017, 120347 ETA XLAM DOL
[6]   Cross laminated timber (CLT): overview and development [J].
Brandner, R. ;
Flatscher, G. ;
Ringhofer, A. ;
Schickhofer, G. ;
Thiel, A. .
EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2016, 74 (03) :331-351
[7]   Cross laminated timber (CLT) diaphragms under shear: Test configuration, properties and design [J].
Brandner, Reinhard ;
Dietsch, Philipp ;
Droescher, Julia ;
Schulte-Wrede, Michael ;
Kreuzinger, Heinrich ;
Sieder, Mike .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 :312-327
[8]   On the distribution of internal forces in single-storey CLT symmetric shear-walls with openings [J].
Casagrande, Daniele ;
Fanti, Riccardo ;
Greco, Marco ;
Gavric, Igor ;
Polastri, Andrea .
STRUCTURES, 2021, 33 :4718-4742
[9]  
Ceccotti A., 2006, 9th World Conference Timber Engineering (WCTE), P805, DOI [DOI 10.1016/0263-8223, 10.1016/0263-8223]
[10]   SOFIE project-3D shaking table test on a seven-storey full-scale cross-laminated timber building [J].
Ceccotti, Ario ;
Sandhaas, Carmen ;
Okabe, Minoru ;
Yasumura, Motoi ;
Minowa, Chikahiro ;
Kawai, Naohito .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (13) :2003-2021