Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database

被引:40
作者
Dickson, John Caddell [2 ,14 ,15 ]
Tossici-Bolt, Livia [16 ]
Sera, Terez [17 ]
de Nijs, Robin [18 ,19 ]
Booij, Jan [1 ,20 ]
Bagnara, Maria Claudia [21 ]
Seese, Anita [22 ]
Koulibaly, Pierre Malick [13 ]
Akdemir, Umit Ozgur [12 ]
Jonsson, Cathrine [11 ]
Koole, Michel [9 ,10 ]
Raith, Maria [8 ]
Lonsdale, Markus Nowak [7 ]
George, Jean [6 ]
Zito, Felicia [5 ]
Tatsch, Klaus [3 ,4 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, Amsterdam, Netherlands
[2] Univ Coll London Hosp NHS Trust, Inst Nucl Med, London NW1 2BU, England
[3] Univ Munich, Dept Nucl Med, Munich, Germany
[4] Municipal Hosp Karlsruhe Inc, Dept Nucl Med, Karlsruhe, Germany
[5] Fdn IRCCS Cagranda Osped Maggiore Policlin, Dept Nucl Med, Milan, Italy
[6] Catholic Univ Louvain, Mt Godinne Med Ctr, Div Nucl Med, Mt Godinne, Belgium
[7] Bispebjerg Hosp, Dept Clin Physiol & Nucl Med, Copenhagen, Denmark
[8] Med Univ Vienna, Dept Nucl Med, Vienna, Austria
[9] Univ Hosp, Div Nucl Med, Louvain, Belgium
[10] Katholieke Univ Leuven, Louvain, Belgium
[11] Karolinska Hosp, Dept Nucl Med, Stockholm, Sweden
[12] Gazi Univ, Fac Med, Dept Nucl Med, Ankara, Turkey
[13] Univ Nice Sophia Antipolis, Nice Nucl Med Federat CHU CAL, Nice, France
[14] UCL, London, England
[15] UCLH NHS Fdn Trust, Inst Nucl Med, London, England
[16] Southampton Univ Hosp NHS Trust, Dept Med Phys & Bioengn, Southampton, Hants, England
[17] Univ Szeged, Dept Nucl Med & Euromed Szeged, Szeged, Hungary
[18] Rigshosp, Neurobiol Res Unit, DK-2100 Copenhagen, Denmark
[19] Univ Copenhagen, Copenhagen, Denmark
[20] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[21] S Martino Univ Hosp, Dept Med Phys, Genoa, Italy
[22] Univ Leipzig, Dept Nucl Med, Leipzig, Germany
关键词
Multi-centre trials; SPECT; I-123-FP-CIT; Normal database; Dopamine transporter; CLINICAL-TRIALS; PET SCANNERS; QUANTIFICATION; QUALIFICATION; RESOLUTION; NETWORK; PHANTOM; IMPACT;
D O I
10.1007/s00259-011-1884-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Multi-centre trials are an important part of proving the efficacy of procedures, drugs and interventions. Imaging components in such trials are becoming increasingly common; however, without sufficient control measures the usefulness of these data can be compromised. This paper describes a framework for performing high-quality multi-centre trials with single photon emission computed tomography (SPECT), using a pan-European initiative to acquire a normal control dopamine transporter brain scan database as an example. Methods A framework to produce high-quality and consistent SPECT imaging data was based on three key areas: quality assurance, the imaging protocol and system characterisation. Quality assurance was important to ensure that the quality of the equipment and local techniques was good and consistently high; system characterisation helped understand and where possible match the performance of the systems involved, whereas the imaging protocol was designed to allow a degree of flexibility to best match the characteristics of each imaging device. Results A total of 24 cameras on 15 sites from 8 different manufacturers were evaluated for inclusion in our multi-centre initiative. All results matched the required level of specification and each had their performance characterised. Differences in performance were found between different system types and cameras of the same type. Imaging protocols for each site were modified to match their individual characteristics to produce comparable high-quality SPECT images. Conclusion A framework has been designed to produce high-quality data for multi-centre SPECT studies. This framework has been successfully applied to a pan-European initiative to acquire a healthy control dopamine transporter image database.
引用
收藏
页码:188 / 197
页数:10
相关论文
共 25 条
[1]  
Benamer HTS, 2000, MOVEMENT DISORD, V15, P503, DOI 10.1002/1531-8257(200005)15:3<503::AID-MDS1013>3.0.CO
[2]  
2-V
[3]   The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials [J].
Boellaard, Ronald ;
Oyen, Wim J. G. ;
Hoekstra, Corneline J. ;
Hoekstra, Otto S. ;
Visser, Eric P. ;
Willemsen, Antoon T. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee ;
Paans, Anne M. ;
Comans, Emile F. I. ;
Pruim, Jan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (12) :2320-2333
[4]   [I-123]FP-CIT SPECT shows a pronounced decline of striatal dopamine transporter labelling in early and advanced Parkinson's disease [J].
Booij, J ;
Tissingh, G ;
Boer, GJ ;
Speelman, JD ;
Stoof, JC ;
Janssen, AGM ;
Wolters, EC ;
vanRoyen, EA .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1997, 62 (02) :133-140
[5]  
Christian PE, 2009, J NUCL MED, V50, p20N
[6]   EANM procedure guidelines for brain neurotransmission SPECT using 123I-labelled dopamine transporter ligands, version 2 [J].
Darcourt, Jacques ;
Booij, Jan ;
Tatsch, Klaus ;
Varrone, Andrea ;
Borght, Thierry Vander ;
Kapucu, Oezlem L. ;
Nagren, Kjell ;
Nobili, Flavio ;
Walker, Zuzana ;
Van Laere, Koen .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (02) :443-450
[7]   Recovery correction for quantitation in emission tomography: a feasibility study [J].
Geworski, L ;
Knoop, BO ;
de Cabrejas, ML ;
Knapp, WH ;
Munz, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (02) :161-169
[8]  
Geworski L, 2002, J NUCL MED, V43, P635
[9]   The Clinical Trials Network of the Society of Nuclear Medicine [J].
Graham, Michael M. .
SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (05) :327-331
[10]   Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT [J].
Hutton, BF ;
Lau, YH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1679-1693