Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [41] Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty
    Blakeney, William G.
    Khan, Riaz J. K.
    Wall, Simon J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) : 1377 - 1384
  • [42] Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis
    Gao, Fuqiang
    Ma, Jinhui
    Sun, Wei
    Guo, Wanshou
    Li, Zirong
    Wang, Weiguo
    KNEE, 2017, 24 (01) : 107 - 115
  • [43] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Stephen M. Howell
    Justin Chen
    Maury L. Hull
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2288 - 2295
  • [44] Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty A FINITE ELEMENT ANALYSIS
    Suh, D-S.
    Kang, K-T.
    Son, J.
    Kwon, O-R.
    Baek, C.
    Koh, Y-G.
    BONE & JOINT RESEARCH, 2017, 6 (11): : 623 - 630
  • [45] Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation
    Boonen, Bert
    Schotanus, Martijn G. M.
    Kerens, Bart
    Hulsmans, Frans-Jan
    Tuinebreijer, Wim E.
    Kort, Nanne P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) : 2809 - 2817
  • [46] Comparison of joint awareness after total knee arthroplasty, medial unicompartmental knee arthroplasty, and high tibial osteotomy: a retrospective study
    Huang, Yiwei
    Ge, Hao
    Peng, Bo
    Feng, Wenjun
    Zhang, Haitao
    Zeng, Yirong
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [47] Does improved instrumentation result in better component alignment in total knee arthroplasty?
    Hassaballa, Mo
    Budnar, Vijaya
    Gbejuade, Herbert
    Learmonth, Ian
    ORTHOPEDIC REVIEWS, 2011, 3 (01) : 9 - 11
  • [48] How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review
    De Valk, Eduard J.
    Noorduyn, Julia C. A.
    Mutsaerts, Eduard L. A. R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3517 - 3528
  • [49] Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment
    Maderbacher, Gunther
    Baier, Clemens
    Benditz, Achim
    Wagner, Ferdinand
    Greimel, Felix
    Grifka, Joachim
    Keshmiri, Armin
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (08) : 1553 - 1560
  • [50] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Klasan, Antonio
    Twiggs, Joshua G.
    Fritsch, Brett A.
    Miles, Brad P.
    Heyse, Thomas J.
    Solomon, Michael
    Parker, David A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1819 - 1824