Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [31] Failure analysis of the tibial component baseplate after total knee arthroplasty
    Oliveira, A. L. L.
    Cueva, E. G.
    Carvalho, R. T.
    ENGINEERING FAILURE ANALYSIS, 2014, 36 : 147 - 154
  • [32] A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty
    Kawaguchi, Kohei
    Inui, Hiroshi
    Yamagami, Ryota
    Kenichi, Kono
    Sameshima, Shin
    Kage, Tomofumi
    Taketomi, Shuji
    Tanaka, Sakae
    KNEE, 2021, 29 : 323 - 331
  • [33] The variability of intramedullary alignment of the femoral component during total knee arthroplasty
    Mihalko, WM
    Boyle, J
    Clark, LD
    Krackow, KA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (01) : 25 - 28
  • [34] Can Isolated Tibial Component Revision Be an Alternative to Isolated Aseptic Loosening of the Tibial Component in Total Knee Arthroplasty?
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (02): : 136 - 138
  • [35] Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk?
    Bove, J. -C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) : 536 - 542
  • [36] Obliquity of tibial component after unicompartmental knee arthroplasty
    Asada, Shigeki
    Inoue, Shinji
    Tsukamoto, Ichiro
    Mori, Shigeshi
    Akagi, Masao
    KNEE, 2019, 26 (02) : 410 - 415
  • [37] Evaluation of anatomic references for tibial sagittal alignment in total knee arthroplasty
    Han, Hyuk Soo
    Chang, Chong Bum
    Seong, Sang Cheol
    Lee, Sahnghoon
    Lee, Myung Chul
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (04) : 373 - 377
  • [38] Alignment and component position after patient-matched instrumentation versus conventional total knee arthroplasty
    Pourgiezis, Nick
    Reddy, Sunil P.
    Nankivell, Mark
    Morrison, Gordon
    VanEssen, John
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02): : 170 - 174
  • [39] Evaluation of anatomic references for tibial sagittal alignment in total knee arthroplasty
    Hyuk Soo Han
    Chong Bum Chang
    Sang Cheol Seong
    Sahnghoon Lee
    Myung Chul Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 373 - 377
  • [40] Correlation between component alignment and short-term clinical outcomes after total knee arthroplasty
    Luan, Yichao
    Zhang, Min
    Ran, Tianfei
    Wang, Huizhi
    Fang, Chaohua
    Nie, Maodan
    Wang, Min
    Cheng, Cheng-Kung
    FRONTIERS IN SURGERY, 2022, 9