Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [21] A proposed new rotating reference axis for the tibial component after proximal tibial resection in total knee arthroplasty
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Inoue, Daisuke
    Taga, Tadashi
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Ueoka, Ken
    Tsuchiya, Hiroyuki
    PLOS ONE, 2018, 13 (12):
  • [22] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Howell, Stephen M.
    Chen, Justin
    Hull, Maury L.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2288 - 2295
  • [23] Investigation of the control of rotational alignment in the tibial component during total knee arthroplasty
    Hanada, Mitsuru
    Furuhashi, Hiroki
    Matsuyama, Yukihiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (06) : 1313 - 1317
  • [24] Can Achilles tendon be used as a new distal landmark for coronal tibial component alignment in total knee replacement surgery? An observational MRI study
    Tiftikci, Ugur
    Serbest, Sancar
    Burulday, Veysel
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 81 - 86
  • [25] The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty
    Nam, Denis
    Vajapey, Sravya
    Nunley, Ryan M.
    Barrack, Robert L.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10) : 2314 - 2319
  • [26] Rotational alignment of the tibial component affects the kinematic rotation of a weight-bearing knee after total knee arthroplasty
    Nakahara, Hiroyuki
    Okazaki, Ken
    Hamai, Satoshi
    Kawahara, Shinya
    Higaki, Hidehiko
    Mizu-uchi, Hideki
    Iwamoto, Yukihide
    KNEE, 2015, 22 (03) : 201 - 205
  • [27] Effect of Tibial Slope on Coronal Alignment in Total Knee Arthroplasty
    Betzle, Christopher J.
    Bringe, Kariline E.
    Horberg, John, V
    Moskal, Joseph T.
    Mann, John W.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 445 - 449
  • [28] Accuracy of the Tibial Component Alignment by Extramedullary System Using Simple Radiographic References in Total Knee Arthroplasty
    Cho, Jin-Ho
    Choi, Jun Young
    Lee, Sung-Sahn
    MEDICINA-LITHUANIA, 2022, 58 (09):
  • [29] Articular surface mounted navigated total knee arthroplasty improves the reliability of component alignment
    Clement, N. D.
    MacDonald, D.
    Burgess, A. G.
    Howie, C. R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1471 - 1477
  • [30] A Coronal Landmark for Tibial Component Positioning With Anatomical Alignment in Total Knee Arthroplasty: A Radiological and Clinical Study
    Gong, Tianlun
    Wang, Ruoyu
    Gong, Song
    Han, Lizhi
    Yi, Yihu
    Wang, Yuxiang
    Xu, Weihua
    FRONTIERS IN SURGERY, 2022, 9