Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [1] Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study
    Mehmet Erdem
    Deniz Gulabi
    Gultekin Sitki Cecen
    Cem Coskun Avci
    Murat Asci
    Fevzi Saglam
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2068 - 2073
  • [2] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08) : 1209 - 1215
  • [3] Improving tibial component alignment in total knee arthroplasty
    Cinotti, G.
    Sessa, P.
    D'Arino, A.
    Ripani, F. R.
    Giannicola, G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3563 - 3570
  • [4] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [5] Improving tibial component coronal alignment using clearly defined anatomical structures in total knee arthroplasty
    Ikeuchi, Masahiko
    Izumi, Masashi
    Aso, Koji
    Sugimura, Natsuki
    Tani, Toshikazu
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (06): : 694 - 698
  • [6] Improving Tibial Component Coronal Alignment During Total Knee Arthroplasty with the Use of a Double-Check Technique
    Ma, De-Si
    Wang, Zhi-Wei
    Wen, Liang
    Ren, Shi-Xiang
    Lin, Yuan
    Zhang, Bo
    ORTHOPAEDIC SURGERY, 2019, 11 (06) : 1013 - 1019
  • [7] The Alignment of the Tibial Component in Total Knee Arthroplasty: Is a Technology-Assisted System Better Than Conventional Instrumentation?
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Roncero-Gonzalez, Sergio
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [8] Reliability of frames of reference used for tibial component rotation in total knee arthroplasty
    Page, Stephen R.
    Deakin, Angela H.
    Payne, Anthony P.
    Picard, Frederic
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 86 - 92
  • [9] Influence of coronal bowing on the lower alignment and the positioning of component in navigation and conventional total knee arthroplasty
    Kobayashi, H.
    Akamatsu, Y.
    Kumagai, K.
    Kusayama, Y.
    Aratake, M.
    Saito, T.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 251 - 256
  • [10] Tibial bowing and tibial component placement in primary total knee arthroplasty in valgus knees: Are we overlooking?
    Palanisami, Dhanasekararaja
    George, Melvin J.
    Hussain, Arif Mohammed
    Chunchesh, M. D.
    Natesan, Rajkumar
    Shanmuganathan, Rajasekaran
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)